Exam4Training

Which issue is causing the storage outage?

An administrator receives a notification that storage in a Nutanix cluster is unavailable. The cluster consists of five nodes and is configured with a Fault-Tolerance level of 1 (FT-1).

Upon investigation, the administrator finds the following:

• All AHV hosts are powered on and the CVMs are running

• Nodes A, B, and C are connected to one top of rack switch

• Nodes D and E are connected to a second top of rack switch

• The cluster status command run on Node A shows that CVM services on nodes D and E are down.

Which issue is causing the storage outage?
A . The default gateway for the CVMs and AHV hosts is down.
B . The switch connecting Nodes D and E is down.
C . The genesis process is down on both Nodes D and E.
D . Nodes D and E are in maintenance mode.

Answer: B

Explanation:

https://hyperhci.com/2020/07/29/nutanix-cluster-services-down-troubleshooting/

Latest NCS-Core Dumps Valid Version with 191 Q&As

Latest And Valid Q&A | Instant Download | Once Fail, Full Refund

Exit mobile version