Exam4Training

Which Fibre Channel port on each SP must be used for native synchronous replication?

An administrator’s Unity system is configured with both a Fibre Channel CNA and a Fibre Channel I/O module.

Which Fibre Channel port on each SP must be used for native synchronous replication?
A . CNA FC port 5
B . I/O module FC port 2
C . CNA FC port 4
D . I/O module FC port 5

Answer: C

Explanation:

Only one FC port can be configured and used for synchronous replication. Once an FC port is assigned, it will continue to act as the synchronous replication port and can never be changed. To determine the FC port used for synchronous replication, in the CLI console, run the command /remote/sys show -detail. Port information, similar to the following example, will appear in the output:

Synchronous FC ports = spb_fc4, spa_fc4

References: https://www.dellemc.com/en-us/documentation/unity-family/unity-p-replication-config/03-unity­rep-br-considerations-syncrep.htm

Latest E20-393 Dumps Valid Version with 297 Q&As

Latest And Valid Q&A | Instant Download | Once Fail, Full Refund

Exit mobile version