Which action should the administrator take to ensure that the desired setting is in place for the client?

An administrator changes the Virus and Spyware Protection policy for a specific group that disables Auto-Protect. The administrator assigns the policy and the client systems apply the corresponding policy serial number. Upon visual inspection of a physical client system, the policy serial number is correct. However, Auto-Protect is still enabled on the client system.

Which action should the administrator take to ensure that the desired setting is in place for the client?
A . Restart the client system
B . Run a command on the computer to Update Content
C . Enable the padlock next to the setting in the policy
D . Withdraw the Virus and Spyware Protection policy

Answer: C

Explanation:

If an administrator modifies the Virus and Spyware Protection policy to disable Auto-Protect, but finds it still enabled on the client, the likely cause is that the setting was not locked. In Symantec Endpoint Protection policies, enabling the padlock icon next to a setting ensures that the policy is enforced strictly, overriding local client configurations. Without this lock, clients may retain previous settings despite the new policy. Locking the setting guarantees that the desired configuration is applied consistently across all clients within the specified group.