Exam4Training

Which action is taken by a switch port enabled for PoE power classification override?

Which action is taken by a switch port enabled for PoE power classification override?
A . When a powered device begins drawing power from a PoE switch port a syslog message is generated.
B . As power usage on a PoE switch port is checked data flow to the connected device is temporarily paused.
C . If a switch determines that a device is using less than the minimum configured power it assumes the device has failed and disconnects.
D . If a monitored port exceeds the maximum administrative value for power, the port is shutdown and err-disabled.

Answer: D

Explanation:

PoE monitoring and policing compares the power consumption on ports with the administrative maximum value (either a configured maximum value or the port’s default value). If the power consumption on a monitored port exceeds the administrative maximum value, the following actions occur:

C A syslog message is issued.

C. The monitored port is shut down and error-disabled.

C. The allocated power is freed.

Reference: https://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst6500/ios/12-2SX/configuration/guide/book/power_over_ethernet.pdf