You install Microsoft System Center Operations Manager (SCOM) and download a sealed management pack.
You receive notifications from a monitor that a critical resource experiences an overload situation. When you check the resource, it is not in an overloaded condition.
You need to add a new threshold value for the resource.
What should you create?
A . an override in an existing management pack
B . an override in a new management pack
C . a monitor in a new management pack
D . a monitor in an existing management pack
Answer: B
Explanation:
Overrides change the configuration of System Center 2016 – Operations Manager monitoring settings for monitors, attributes, object discoveries, and rules. As a best practice, save all overrides for each sealed management pack to an unsealed management pack that is named ManagementPack_Override, where ManagementPack is the name of the sealed management pack to which the overrides apply.
References:
https://docs.microsoft.com/en-us/system-center/scom/manage-mp-override-rule-monitor?view=sc-om
https://docs.microsoft.com/en-us/system-center/scom/manage-mp-create-unsealed-mp?view=sc-om-1807