FabricPath switch-id is 25 and load-balance is configured for L3/L4 and rotate amount is 14 byte.
What information is true about FabricPath switch-id?
A . FabricPath topology requires manual configuration of switch-id which has a range from 1 to 4095
B . Every FabricPath must have a manually configured switch-id for it to form a FabricPath topology
C . FabricPath topology requires manual configuration of switch-id which has a range from 1 to 4099
D . You do not have to manually assign a switch ID unless you are running a virtual port channel plus (vPC+) because the system assigns a switch ID for you when you enable FabricPath
Answer: D
Explanation:
fabricpath switch-id (vPC)
To configure a virtual port channel plus (vPC+) switch ID, use the fabricpath switch-id command. To remove the FabricPath switch from a vPC domain, use the no form of this command.
fabricpath switch-id switch-id
no fabricpath switch-id [ switch-id ]
Usage Guidelines
You do not have to manually assign a switch ID (unless you are running a vPC+); the system assigns a switch ID for you when you enable FabricPath.
Note You must assign the same vPC+ switch ID to each of the two vPC+ peer devices before they can form an adjacency.
This command requires an Enhanced Layer 2 license.
Examples
This example shows how to configure a vPC+ switch ID on a FabricPath-enabled device:
switch# configure terminal
switch(config)# vpc domain 1
switch(config-vpc-domain)# fabricpath switch-id 1
Configuring fabricpath switch id will flap vPCs. Continue (yes/no)? [no]