What is the maximum recommended MTU value for all non-management VLANs within VMware Cloud Foundation?
What is the maximum recommended MTU value for all non-management VLANs within VMware Cloud Foundation?A . MTU 15000B . MTU 15000C . MTU 9000D . MTU 16000View AnswerAnswer: C
Which architectural deployment type/model is supported?
Which architectural deployment type/model is supported?A . In a standard VMware Cloud Foundation 4.x architecture, a VMware Lifecycle Manager appliance is deployed in each Workload DomainB . In a standard VMware Cloud Foundation 4 x architecture, each Workload Domain hosts its own vCenter server.C . In a consolidated VMware Cloud...
Which two constraints impact this design?
An architect is tasked with designing a new VMware Cloud Foundation environment. The company will purchase vSAN Ready Nodes for the management cluster but wants to make use of existing investments where possible, including a significant investment made recently in an all-flash storage array and 16GB FC fabric. The design...
Which two prerequisites are required to create vSphere with Tanzu namespace? (Choose two.)
Which two prerequisites are required to create vSphere with Tanzu namespace? (Choose two.)A . The Primary Workload Network must be availableB . Verify that the administrator has the prrvilege Namespaces. Manage label on the Supervisor ClusterC . Kubemetes clusters and objects must have access to the company NTP and company...
Which two steps must be performed to facilitate imaging with the VMware Imaging Appliance?
An administrator has been tasked with adding capacity to an existing workload domain. The new hosts have hosts arrived but will need to be prepared before they can be added to VMware Which two steps must be performed to facilitate imaging with the VMware Imaging Appliance? (Choose two)A . Configure...
Which cluster expansion type should be selected when expanding the second cluster using the SDDC Manager UI?
The administrator for an existing VMware Cloud Foundation instance has one management domain (sfo-m01) and one workload domain (sfo-w01). The workload domain consists of two vSphere clusters (sfo-w01-ci01 and sfo-w01-cl02) using vSAN as principle storage. The workload domain also includes an NSX-T Edge Cluster deployed in the default cluster(sfo-w01-c01) of...
What is the maximum recommended MTU value for all non-management VLANs within VMware Cloud Foundation?
What is the maximum recommended MTU value for all non-management VLANs within VMware Cloud Foundation?A . MTU 15000B . MTU 15000C . MTU 9000D . MTU 16000View AnswerAnswer: C
What is the valid server type within SDDC Manager that should be used when registering an external server for the file-based backup of VMware NSX Managers?
What is the valid server type within SDDC Manager that should be used when registering an external server for the file-based backup of VMware NSX Managers?A . SFTPB . FTPC . NFSD . HTTPSView AnswerAnswer: A
Which two steps must be performed to facilitate imaging with the VMware Imaging Appliance?
An administrator has been tasked with adding capacity to an existing workload domain. The new hosts have hosts arrived but will need to be prepared before they can be added to VMware Which two steps must be performed to facilitate imaging with the VMware Imaging Appliance? (Choose two)A . Configure...
Which two constraints impact this design?
An architect is tasked with designing a new VMware Cloud Foundation environment. The company will purchase vSAN Ready Nodes for the management cluster but wants to make use of existing investments where possible, including a significant investment made recently in an all-flash storage array and 16GB FC fabric. The design...