Which CLI command disables the nsxcli time out value on NSX Manager?
An NSX administrator noticed that the nsxcli command times out after 600 secs of idle time. Which CLI command disables the nsxcli time out value on NSX Manager?A . set cli-timeout 0B . set cli-timeout enabledC . set cli-timeout disabledD . set cli-timeout 1View AnswerAnswer: A Explanation: " https://vdc-download.vmware.com/vmwb-repository/dcr-public/cc42e3c1-eb34-4567-a916-147e79798957/8264605c-a5e1-49a8-b603-cc78621eeeab/cli.html#set%20cli-timeout%20%3Ctimeout%3E https://www.virten.net/2020/06/quick-tip-remove-nsx-t-ssh-and-http-session-timeout/
Which three can an administrator define in a transport node profile? (Choose three.)
Which three can an administrator define in a transport node profile? (Choose three.)A . Logical RouterB . Segment ProfileC . SegmentD . Uplink ProfileE . VDS switch configurationF . N-VDS switch configurationView AnswerAnswer: D,E,F
Which is correct when deploying a NSX Edge in a KVM only environment?
Which is correct when deploying a NSX Edge in a KVM only environment?A . deploy NSX Edge VM with QCOW2 imageB . deploy NSX Edge VM with ISO imageC . deploy NSX Edge on a bare-metal serverD . deploy NSX Edge VM with OVF templateView AnswerAnswer: C
Which host log files could be exported to a remote syslog server?
An NSX administrator would like to configure syslog for a KVM transport node. Which host log files could be exported to a remote syslog server?A . /var/log/vmware/nsx-syslogB . /var/log/cfgAgent.logC . /var/log/nsx-audit.logD . /var/log/cloudnet/nsx-ccp.logView AnswerAnswer: A
Which two commands must be executed to check BGP neighbor status?
A customer has a network where BGP has been enabled and the BGP neighbor is configured on the Tier-0 Gateway. A NSX-T Data Center administrator used the get logical-routers command to retrieve this information: Which two commands must be executed to check BGP neighbor status? (Choose two.)A . vrf 3B...
When a stateful service is enabled for the first time on a Tier-0 Gateway, what happens on the NSX Edge node?
When a stateful service is enabled for the first time on a Tier-0 Gateway, what happens on the NSX Edge node?A . SR and DR doesn’t need to be connected to provide any stateful services.B . DR is instantiated and automatically connected with SD . SR is instantiated and automatically...
Which two statements describe the characteristics of an Edge Cluster in NSX-T 3.0 Data Center? (Choose two.)
Which two statements describe the characteristics of an Edge Cluster in NSX-T 3.0 Data Center? (Choose two.) A. can have a maximum of 8 edge nodes B. must have only active-active edge nodes C. can have a maximum of 10 edge nodes D. can contain multiple types of edge nodes...
Which two BGP configuration parameters can be configured in the VRF Lite gateways? (Choose two.)
Which two BGP configuration parameters can be configured in the VRF Lite gateways? (Choose two.)A . Route AggregationB . Route DistributionC . Graceful RestartD . BGP NeighborsE . Local ASView AnswerAnswer: A,D Explanation: The following parameters are inherited from the default Tier-0 gateway and cannot be modified at the VRF...
What privileges does this user have in the system?
A user is assigned these two roles in NSX Manager: ✑ LB Admin ✑ Network Engineer What privileges does this user have in the system?A . read permissions on all networking services and full access permissions on load balancing featuresB . full access permissions on all networking services and full...
Which CLI command does an NSX administrator run on the NSX Manager to generate support bundle logs if the NSX UI is inaccessible?
Which CLI command does an NSX administrator run on the NSX Manager to generate support bundle logs if the NSX UI is inaccessible?A . get support-bundle file vcpnv.tgzB . set support-bundle file vcpnv.tgzC . vm-supportD . esxcli system syslog config logger set --id=nsxmanagerView AnswerAnswer: A Explanation: https://vdc-download.vmware.com/vmwb-repository/dcr-public/cc42e3c1-eb34-4567-a916-147e79798957/8264605c-a5e1-49a8-b603-cc78621eeeab/cli.html