VMware 5V0-22.21 VMware vSAN Specialist Online Training
VMware 5V0-22.21 Online Training
The questions for 5V0-22.21 were last updated at Nov 19,2024.
- Exam Code: 5V0-22.21
- Exam Name: VMware vSAN Specialist
- Certification Provider: VMware
- Latest update: Nov 19,2024
A vSAN administrator has three available racks and six vSAN hosts and needs to protect against a rack failure while maximizing resources.
Which two strategies should the vSAN administrator use to achieve this goal? (Choose two.)
- A . RAID-5/FTT=1
- B . vSAN stretched cluster
- C . Specify fault domains
- D . RAID-6/FTT=2
- E . 2-node configuration
A VMware vSAN administrator is configuring advanced monitoring with VMware vRealizeOperations Manager and has the following requirement:
• Ability to receive analytical information from the hard drive to determine a possible future failure of the hard drive.
What should be enabled for data collection when configuring the vSAN Adapter Instance?
- A . IOPS (Input/Output Operations Per Second)
- B . DST (Disk Self-Test)
- C . SMART (Self-Monitoring, Analysis and Reporting Technology)
- D . SSP (Storage Service Provider)
A vSAN administrator needs to find the metrics for objects containing data served up by the vSAN iSCSI service.
On which level should the vSAN administrator look?
- A . Cluster
- B . Virtual Machine
- C . vCenter Server
- D . vSAN iSCSI Object
A vSAN administrator needs to find the metrics for objects containing data served up by the vSAN iSCSI service.
On which level should the vSAN administrator look?
- A . Cluster
- B . Virtual Machine
- C . vCenter Server
- D . vSAN iSCSI Object
A currently-deployed vSAN cluster must deliver persistent storage to be used by vSphere with Tanzu. The administrator needs to properly configure the vSAN Direct Configuration for this solution.
Which three steps should be taken? (Choose three.)
- A . Configure vSAN File Services for vSAN Direct.
- B . Assign the storage policy to the container VMs.
- C . Create a storage policy for vSAN Direct.
- D . Create a vSAN storage policy with FTT=0.
- E . Assign the storage policy to the namespace.
- F . Claim unused disks for vSAN Direct.
After a recent data loss event, the IT department plans to deploy a DR site using vSphere Replication with vSAN providing the storage backend.
The architect would like to know how many components will be created based on the following configuration:
✑ 2x 100 GB VMDK
✑ RAID 1 vSAN Storage Policy
✑ 4x Point in Time snapshots
How many components will be created?
- A . 32
- B . 24
- C . 16
- D . 8
A storage administrator is facing degraded performance for the VMs running on a vSAN enabled vSphere Cluster and needs an out-of-the-box tool to identify the root cause of the problem.
Which tool should be used?
- A . top
- B . esxcli
- C . vmkfstools
- D . vsantop
A vSAN administrator is looking at adding a new vSAN cluster with hosts that have 512GB memory.
What is the minimum requirement for the node’s flash boot device?
- A . 16GB
- B . 128GB
- C . 32GB
- D . 4GB
A host in the cluster experiences a permanent NIC failure, and the replacement part will not arrive until the next morning. The administrator needs to ensure the availability of the production workload at all times.
Which step should be taken by the administrator to meet this goal?
- A . Shut down the production VMs.
- B . Perform a live vMotion to another host.
- C . Disable the vSAN Service on the VMkernel port.
- D . Enter Maintenance Mode with ‘Full Data Migration’
A vSAN administrator has been tasked with troubleshooting an application in a Hybrid vSAN environment. The application is I/O intensive, and the magnetic capacity devices may be playing a role in slow performance, so the administrator decides to take action to help resolve the problem.
Which action should the administrator take?
- A . Change the Default Storage Policy to have stripe width of 13.
- B . Modify the stripe width for the application on the advanced settings for the VM.
- C . Add more magnetic capacity devices in the affected host.
- D . Increase the stripe width based on the number of capacity devices within the disk group.