VMware 5V0-21.21 VMware HCI Master Specialist Online Training
VMware 5V0-21.21 Online Training
The questions for 5V0-21.21 were last updated at Dec 19,2024.
- Exam Code: 5V0-21.21
- Exam Name: VMware HCI Master Specialist
- Certification Provider: VMware
- Latest update: Dec 19,2024
In a stretched vSAN cluster, how is Read Locality established after fail over to the secondary site?
- A . 100% of the reads comes from vSAN hosts on the local site
- B . 50% of the reads comes from vSAN hosts on the local site
- C . 100% of the reads comes from vSAN hosts on the remote site
- D . 50% of the reads comes from vSAN hosts on the remote site
In a vSAN stretched cluster, which value must be set in the vSAN policy if there is no requirement for data mirroring across sites?
- A . SFTT = 0
- B . SFTT = 1
- C . PFTT = 1
- D . PFTT = 0
An architect needs to automate an infrastructure that supports VMware Horizon as well as VMware Tanzu.
Which solution mandates the use of VMware vSAN?
- A . VMware Cloud Foundation
- B . VMware Horizon
- C . VMware Tanzu
- D . VMware vRealize Automation
An administrator is setting up vSAN file services on a vSAN cluster.
Which two security policies on the distributed port groups are automatically enabled in the process? (Choose two.)
- A . Forged Transmits
- B . Promiscuous Mode
- C . DVFiltering
- D . Jumbo Frames
- E . MacLearning
An administrator has been tasked to reboot a node in an encrypted vSAN cluster. The vSAN disk groups on that node become locked after rebooting the node.
Which step should be performed to exit the locked state?
- A . Manually replace the Host Encryption Key (HEK) of each affected host.
- B . Restore the communication with the KMS server, and re-establish the trust relationship.
- C . Replace the caching device in each affected disk group.
- D . Run /etc/init.d/vsanvpd restart to rescan the VASA providers.
A customer is planning to deploy a vSAN cluster to host their in-house distributed ERP system.
The hardware specifications for their server nodes include:
* 2 x Intel Xeon CPU E5-2697 v3 @ 2.60GHz
* 1TB memory
Which boot device is supported for the vSAN ESXi nodes for this customer?
- A . A 16GB single-level cell (SLC) SATADOM device must be used.
- B . A 4GB USB or SD device must be used.
- C . A 16GB multiple-level cell (MLC) SATADOM device must be used.
- D . ESXi Hosts must boot from a PMEM device.
A company hosts a vSAN 7 stretched cluster for all development workloads. The original sizing of a maximum of 250 concurrent workloads in the vSAN cluster is no longer sufficient and needs to increase to at least 500 concurrent workloads within the next six months.
To meet this demand, the original 8-node (4-4-1) cluster has recently been expanded to 16 nodes (8-8-1).
Which three additional steps should the administrator take to support the current growth plans while minimizing the amount of resources required at the witness site? (Choose three.)
- A . Add the new vSAN witness appliance to vCenter Server.
- B . Deploy a new large vSAN witness appliance at the witness site.
- C . Configure the vSAN stretched cluster to use the new vSAN witness.
- D . Deploy a new extra large vSAN witness appliance at the witness site.
- E . Upgrade the vSAN stretched cluster to vSAN 7.0 U1.
- F . Configure the new vSAN witness as a shared witness appliance.
Upon investigating a workload performance issue, a vSAN administrator observed a high backend IOPs on a vSAN cluster.
Which two causes explain this behavior? (Choose two.)
- A . The cluster DRS threshold has been set to Aggressive.
- B . There is a vSAN node failure.
- C . The vSAN Resync throttling is enabled.
- D . The object repair timer value has been increased.
- E . The vSAN policy protection level has changed from FTT=0 to FTT=1.
An administrator wants to check the performance metrics for the workloads and their virtual disks that are running on a vSAN cluster, but no statistical charts are displayed in the vSphere client.
Why is this behavior being seen?
- A . vSAN network diagnostic mode is not enabled.
- B . vSAN proactive tests haven’t been run yet.
- C . vSAN performance service is turned off.
- D . vSAN performance verbose mode is not enabled.
During a maintenance action on a vSAN node, a vSAN administrator noticed that the default repair delay time is about to be reached.
Which two commands must be run to extend the time? (Choose two.)
- A . /etc/init.d/vsanmgmtd restart
- B . esxcli system settings advanced set -o /VSAN/ClomRepairDelay -i 50
- C . esxcli system settings advanced set -o /VSAN/ClomRepairDelay -i 80
- D . /etc/init.d/clomd restart
- E . /etc/init.d/vsanobserver restart