VMware 3V0-41.19 VMware Advanced Design NSX-T Data Center 2.4 Exam Online Training
VMware 3V0-41.19 Online Training
The questions for 3V0-41.19 were last updated at Nov 22,2024.
- Exam Code: 3V0-41.19
- Exam Name: VMware Advanced Design NSX-T Data Center 2.4 Exam
- Certification Provider: VMware
- Latest update: Nov 22,2024
Which NSX-T feature is used to allocate the network bandwidth to business-critical applications and to resolve situations where several types of traffic compete for common resources?
- A . LAG Uplink Profile
- B . Transport Node Profiles
- C . LLDP Profile
- D . Network I/O Control Profiles
An architect is helping an organization with the Physical Design of an NSX-T Data Center solution and resolving a network throughput bottleneck.
This information was gathered during a workshop:
– A VM running a business critical application Is peaking at ~5Gbps
– Current host uplink is configured as Active/Standby with two 10Gb NICs.
– The installed server NIC model does not support GENEVE offload.
– All VM traffic is East/West.
– The business critical application VM communicates with multiple client VMs.
Which should the architect recommend to improve vSphere VM throughput?
- A . Configure the Transport Node Uplink Profile to use a Load Balance Source teaming policy with two active uplinks.
- B . Deploy an additional Edge Node to the Edge Node Cluster.
- C . Replace the existing network switches and routers with newer higher-performance.
- D . Replace the existing NICs with a model that supports GENEVE offload.
Which three must be taken into consideration when creating a Logical Design for a planned migration? (Choose three.)
- A . A transport node can attach single VLAN transport zones with single N-VDS.
- B . An N-VDS with the same name can be attached to both Overlay and VLAN transport zones.
- C . An N-VDS can attach to both an Overlay and a VLAN transport zone to a N-VDS having different name/s.
- D . An N-VDS can only attach to a single Overlay transport zone.
- E . An N-VDS can only attach to a single VLAN transport zone.
- F . An N-VDS can only attach to a multiple VLAN transport nodes.
An architect is helping an organization with the Logical Design of an NSX-T Data Center solution.
This information was gathered during the Assessment Phase:
– Maximum performance and availability is required between the physical and virtual network.
– Load Balancing service is required for back-end web servers.
– NAT is required.
Which should the architect include in their design?
- A . Deploy a Tler-1 gateway and connect It to an Active/Active Tier-0 gateway with ECMP configured.
- B . Deploy an Active/Active Tier-0 gateway and configure ECMP.
- C . Create two separate VLANs to connect the Tier-0 gateway upstream traffic and configure ECMP.
- D . Deploy an Active/Passive Tier-0 gateway and configure ECMP.
Which is associated with the Discover Task of the Engagement Lifecycle?
- A . Create and document the logical and virtual design.
- B . Gather and document requirements, assumptions and constraints.
- C . Build, deploy, implement and test the design.
- D . Measure performance against customer’s requirements.
An NSX-T architect is working with a customer who wants to improve performance and future-proof
their workloads with a multi-site architecture.
A current-state analysis captured this information:
– Latency between sites Is 160ms.
– Bandwidth is 2Gbps.
– The MTU is 1600.
What two VMware design recommendations should the architect recommend to the organization to achieve future-proofing? (Choose two.)
- A . Latency must be less than 150ms.
- B . Bandwidth must be at least 10Gbps.
- C . MTU is recommended to be 9000.
- D . MTU must be at least 1700.
- E . Latency RTT is acceptable.
An architect is helping an organization with the Logical Design of an NSX-T Data Center solution.
This information was gathered during the Assessment Phase:
– There Isn’t much budget available for a new off-shore site.
– The new site is decentralized and no communication with the main data center is required.
– The design will need to cater for availability, upgrades, and failure scenarios.
Which three should the architect recommend In their design? (Choose three.)
- A . Collapse the Management/Edge/Compute cluster.
- B . A Shared Edge/Management cluster and one for Compute.
- C . Separate the hosts physical NICs for VSS and N-VDS.
- D . Install a minimum 4 ESXi hosts In the site.
- E . Make all pNICs part of N-VDS and VMKs will be migrated.
- F . Install a minimum of 6 ESXi hosts in the site.
Which three assessment findings are part of a Conceptual Design? (Choose three.)
- A . assumptions
- B . vendor model
- C . justifications
- D . constraints
- E . host names
- F . risks
An architect is helping an organization with the Physical Design of an NSX-T Data Center solution.
This information was gathered during a workshop:
– Some workloads should be moved to a Cloud Provider.
– Extend network’s VLAN or VNI across sites on the same broadcast domain.
– Enable VM mobility use cases such as migration and disaster recovery without IP address changes.
– Support 1500 byte MTU between sites.
Which should the architect include in their design?
- A . SSL VPN
- B . Reflexive NAT
- C . L2 VPN
- D . Load Balancer
An architect is helping an organization with the Logical Design of an NSX-T Data Center solution.
This information was gathered during the Assessment Phase:
– Customer Is concerned with NSX Manager availability.
– 3 cabinets/racks are available in the data center.
– No integration with 3rd party solution is required.
– There is no budget for physical equipment acquisition.
– The 3 cabinets/racks do not share the same L2 domain.
Which three should the architect include in their design to address the customer’s concern with NSX Manager availability? (Choose three.)
- A . Use another NSX Manger IP in case an appliance falls.
- B . Deploy 2 cold standby NSX Manager appliances in rack 2/3.
- C . Deploy an NSX Manager Appliance per rack and cluster them.
- D . Use a physical/internal load-balancer with the cluster.
- E . Use separate IP per NSX Manager appliance per rack.
- F . Deploy a single active NSX Manager appliance in rack 1.