USGBC LEED AP ID+C LEED AP Interior Design + Construction (LEED AP ID+C) V4 Online Training
USGBC LEED AP ID+C Online Training
The questions for LEED AP ID+C were last updated at Apr 10,2025.
- Exam Code: LEED AP ID+C
- Exam Name: LEED AP Interior Design + Construction (LEED AP ID+C) V4
- Certification Provider: USGBC
- Latest update: Apr 10,2025
The project team for a bank project located in a mall is wondering whether they can earn Location and Transportation Credit Surrounding Density and Diverse Uses, Option 2. Diverse Uses.
When evaluating a map of nearby diverse uses, which of the following would you recommend to be entered in the calculation?
- A . Health club, Laundromat, Post office, Restaurant
- B . Hair salon, Movie Theater, Pharmacy, Restaurant
- C . Clothing store, Commercial office, Eye doctor, Supermarket
- D . Convenience store, Furniture store, Hardware store, Pharmacy
In the pre-design phase, a plumbing engineer identified that the low-flow fixtures which met the Owner’s requirements could achieve total reductions in indoor water usage of 39%.
Which strategies should be assessed to meet the Owner’s Project Requirements goals of 45% reduction?
- A . Switching from municipally supplied potable water to potable well water on-site
- B . Reducing irrigation needs by planting native species and drought-tolerant species
- C . Reducing potable water supply by limiting occupant access to drinking fountains and public restrooms
- D . Reducing process water demand by assessing kitchen and laundry equipment selection and operational. schedules
Which project team members should be present at a goal setting workshop when using an Integrative Process project approach?
- A . Only the design team members
- B . Owner, designer, and contractor
- C . All principal project team members
- D . Project team members with LEED® Credentials
For the achievement of Materials and Resources Credit, Interiors Life Cycle Impact Reduction, Option 1. Interior Reuse, how are hazardous materials accounted for in the calculation?
- A . Included in the numerator only
- B . Included in the denominator only
- C . Included in both the numerator and denominator
- D . Excluded from both the numerator and denominator
Which of the following would contribute to the Location and Transportation Credit, Surrounding Density and Diverse Uses, Option 2. Diverse Uses?
- A . An existing bus stop located 1/4 mi. (0.40 km) away from the LEED project’s main entrance
- B . An existing restaurant that is 3/4 mi. (1.20 km) away from the LEED project’s main entrance
- C . An existing fast-food restaurant with no drive-in service located 1/8 mi. (0.20 km) away from the LEED project’s main entrance
- D . A planned school that will be occupied within 18 months of the date of the LEED project’s initial certificate of occupancy and is located 1/4 mi. (0.40 km) away from the LEED project’s main entrance
The project material costs for Building Product Disclosure and Optimization cost-based credits are
- A . actual costs, furniture included
- B . default costs, 30% of total construction cost
- C . actual costs, furniture optional
- D . default costs, 40% of total construction cost
Best practices recommend that the LEED AP confirm that minimum program requirements have been met
- A . as part of the discovery phase
- B . as part of the final certification submittal
- C . after the design phase but before construction
- D . after the Commissioning (Cx) review but before design phase submittal
What should a team focus on first to significantly improve energy performance or achieve the lowest possible operation cost?
- A . Choosing energy efficient systems
- B . Conducting a simple box energy model
- C . Implementing passive design strategies
- D . Performing commissioning of energy systems
A project is pursuing Indoor Environmental Quality Credit, Interior Lighting, Option 1. Lighting Control.
Which lighting control could the design team specify to meet the credit requirements for open-office workstations?
- A . Standard on-off switches at each workstation
- B . Plug-in task light at each workstation that allow for on, off and a 50% light level
- C . Overhead lighting for the open-office space with fully automatic dimming via daylight sensors for the space
- D . Overhead lighting for the open-office space with controls that allow for on, off and a 50% light level for the space
A tenant moving into an existing building will need to install new HVAC, power, lighting systems and other equipment.
Which of the following resources would help the tenant meet the requirements of Energy and Atmosphere Credit, Optimize Energy Performance?
- A . Green Seal Standard 11
- B . ANSI/ASHRAE Standard 62.1-2010
- C . ANSI/ASHRAE/IESNA Standard 90.1-2010
- D . South Coast Air Quality Management District (SCAQMD)