Modifying the micro-module layout view on ECC800 supports simultaneous editing by ( ) users.
Modifying the micro-module layout view on ECC800 supports simultaneous editing by ( ) users.A . 1B . 2C . 3D . 4View AnswerAnswer: A
What are the types of scaling strategies for elastic scaling? (Multiple Choice)
What are the types of scaling strategies for elastic scaling? (Multiple Choice)A . Timing strategyB . Warning strategyC . Random strategyD . Cycle strategyView AnswerAnswer: ABD
The cloud dedicated line service is a dedicated line network service that establishes a connection between the local data center and the public cloud. What types of dedicated lines are currently supported by the cloud dedicated line?
The cloud dedicated line service is a dedicated line network service that establishes a connection between the local data center and the public cloud. What types of dedicated lines are currently supported by the cloud dedicated line?A . IPSec VPNB . OSPF VPNC . MPLS VPND . SSL VPNView AnswerAnswer:...
Which is not part of the routine maintenance item of the ECC800 power module?
Which is not part of the routine maintenance item of the ECC800 power module?A . Check if the power indicator light is normalB . Check the ECC800 module fanC . Check whether the power wiring is looseD . Create a micromodule plan viewView AnswerAnswer: D
The height of the ECC800 collector is () U.
The height of the ECC800 collector is () U.A . 1B . 2C . 3D . 4View AnswerAnswer: A
When the outdoor units of Huawei air-cooled air conditioners are installed horizontally, the distance between the two outdoor units is ≥ () MM.
When the outdoor units of Huawei air-cooled air conditioners are installed horizontally, the distance between the two outdoor units is ≥ () MM.A . 400B . 800C . 1200D . 2000View AnswerAnswer: C
The function of the check valve in the NetCol5000-A air conditioning system is ( ).
The function of the check valve in the NetCol5000-A air conditioning system is ( ).A . Filtration of impurities in the systemB . Controlling refrigerant flowC . Effective control of gas or liquid backflowD . Protect the water pumpView AnswerAnswer: C
The flexible file service supports the standard ( ) protocol.(Multiple Choice)
The flexible file service supports the standard ( ) protocol.(Multiple Choice)A . HTTPB . CIFSC . CFTPD . NFSv3View AnswerAnswer: BD
What are the product advantages of VPC? (Multiple Choice)
What are the product advantages of VPC? (Multiple Choice)A . Flexible deploymentB . Dynamic BGPC . Safe isolationD . Support hybrid cloud deploymentView AnswerAnswer: ABCD
When installing NETECL5000-A35KW, generally at least pre-charge () KG refrigerant.
When installing NETECL5000-A35KW, generally at least pre-charge () KG refrigerant.A . 5B . 8C . 10D . 12View AnswerAnswer: C