The correct coding for insertion of a dialysis catheter into the right internal jugular vein with the tip ending in the cavoatrial junction is

The correct coding for insertion of a dialysis catheter into the right internal jugular vein with the tip ending in the cavoatrial junction is
A . 05HM33Z Insertion of infusion device into right internal jugular vein, percutaneous approach
B . 02H633Z Insertion of infusion device into right atrium, percutaneous approach
C . 05HP33Z Insertion of infusion device into right external jugular vein, percutaneous approach
D . 02HV33Z Insertion of infusion device into superior vena cava, percutaneous approach

Answer: A

Explanation:

According to the ICD-10-PCS Reference Manual 2023, the insertion of a dialysis catheter into the right internal jugular vein with the tip ending in the cavoatrial junction is coded as follows1:

The first character 0 indicates the Medical and Surgical section.

The second character 5 indicates the Extracorporeal or Systemic Assistance and Performance root operation, which is defined as "Putting in or on a device that completely takes over a body function by extracorporeal means"1.

The third character H indicates the Central Vein body system, which includes the internal jugular vein1.

The fourth character M indicates the Infusion Device device value, which is defined as "A device that is inserted into a body part to deliver fluids or other substances to a body part or into the circulation"1.

The fifth character 3 indicates the Right Internal Jugular Vein body part value, which is the specific site of the procedure1.

The sixth character 3 indicates the Percutaneous approach, which is defined as "Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure"1.

The seventh character Z indicates No Qualifier, which means there is no additional information necessary to complete the code1.

Therefore, the correct coding for insertion of a dialysis catheter into the right internal jugular vein with the tip ending in the cavoatrial junction is 05HM33Z.

References:

ICD-10-PCS Reference Manual 20231