Which of the following is your BEST course of action?

After construction on a project has begun, the client asks you to change the wallcovering originally specified to one that does not meet current code requirements. Which of the following is your BEST course of action?A . Research available products that are similar to the requested product and meet the...

August 11, 2020 No Comments READ MORE +

In which situation should you use a construction change directive?

In which situation should you use a construction change directive?A . To request an electrical contractor not listed by the contractor in the bid [tender] documentsB . To request pricing for an additional receptacle per the client's requestC . To provide additional dimensions to the contractor regarding a receptacle locationD...

August 10, 2020 No Comments READ MORE +

Why are addenda issued?

Why are addenda issued?A . To provide additional information not included in the bid packageB . To inform potential bidders about acceptable alternatesC . To obtain additional informationD . To request a change during constructionView AnswerAnswer: A

August 8, 2020 No Comments READ MORE +

In which space is emergency lighting REQUIRED?

In which space is emergency lighting REQUIRED?A . ElevatorsB . Private officesC . Egress corridorsD . RestroomsView AnswerAnswer: C

August 7, 2020 No Comments READ MORE +

Why is it necessary to indicate the placement of the proposed elevator and stairway in a preliminary plan?

Why is it necessary to indicate the placement of the proposed elevator and stairway in a preliminary plan?A . To ensure an acceptable location to meet all codesB . To verify the client's budget constraintsC . To establish the structural support work requiredD . To ensure accessibility and visibility to...

August 5, 2020 No Comments READ MORE +

Which light and color characteristic would be MOST effective to enhance way-finding in a senior living facility?

Which light and color characteristic would be MOST effective to enhance way-finding in a senior living facility?A . BrightnessB . HueC . ContrastD . SaturationView AnswerAnswer: C

August 5, 2020 No Comments READ MORE +

What factors are MOST important in determining the locations of individual workstations within departments?

What factors are MOST important in determining the locations of individual workstations within departments?A . Planning and design conceptsB . Company image and employee statusC . Work relationships and job adjacenciesD . Client's business and communication patternsView AnswerAnswer: C

August 4, 2020 No Comments READ MORE +

What should you do?

Your client has a very limited budget for design services, and the scope of the project warrants mechanical and electrical engineering specification. What should you do?A . Reduce your scope to reduce the fee, and contract with a mechanical/electrical engineer for an outline specification.B . Recommend that the client work...

August 2, 2020 No Comments READ MORE +

What portion of a contract typically outlines the designer's responsibilities to the client?

What portion of a contract typically outlines the designer's responsibilities to the client?A . Scope of servicesB . Project descriptionC . Terms and conditionsD . Compensation scheduleView AnswerAnswer: A

August 1, 2020 No Comments READ MORE +

Which event triggers the issuance of a certificate of occupancy?

Which event triggers the issuance of a certificate of occupancy?A . Construction work is complete except for fire alarm testing.B . The contractor sends you a pay request for 100% complete work.C . The owner wants to move into part of the space before the rest is finished.D . The...

August 1, 2020 No Comments READ MORE +