What is the minimum number of zones required to accomplish this task?

You are planning for a new AFF A700 2-node switchless FC solution with two Cisco 9100 switches. Each AFF A700 will have one 16 Gb port connected to each Cisco 9100 switch and four FC LIFs per physical port. You want to guarantee recovery from connection loss on a NetApp...

May 12, 2023 No Comments READ MORE +

What caused the problem?

Exhibit: cl01::>igroup show Cvserver svm1 VserverIgroup Protocol OS Type Initiators --------- ------------- ------ -- --------- ----------------- -------------------- svm1 esx_cluster mixed vmware 20:00:00:25:b5:11:a0:01, 20:00:00:25:b5:11:b0:01, iqn.1998-01.com.vmware:esx02 cl01::> A customer is provisioning storage for two ESXi hosts using FCoE with CNA adapters. The customer mapped the LUN to the igroup shown in the...

May 12, 2023 No Comments READ MORE +

In this scenario, what would be the reason for the disconnects?

A company has 20 ESX hosts. Ten of the hosts are connected using FC, and the rest are connected over iSCSI. The FC host HBA queue depth is set to 32, and the iSCSI LUN queue depth is set to 64. The FC hosts are now experiencing random connectivity issues....

May 12, 2023 No Comments READ MORE +

Referring to the exhibit, what happens when you change the type for port 1a from target to initiator?

Referring to the exhibit, what happens when you change the type for port 1a from target to initiator? A . The port type for 1a changes to initiator, and you must reboot the controller for the changes to take effect. B. You receive an error message that you must take...

May 12, 2023 No Comments READ MORE +

What will happen if the volume vs_iscsi_exch01 reaches 85% used?

75 GB Used Size: 144 KB Used Percentage: 5% Volume Nearly Full Treshold Percent: 95% Volume Full Treshold Percent: 98% Maximum Autosize (for flexvolvs only): 6GB (DEPRECATED) CAutosize Increment (for flexvolvs only): 256MB Minimum Autosize: 5GB Autosize Grow Threshold Percentage: 85% Autosize Shrink Threshold Percentage: 50% Autosize Mode: off Autosize...

May 12, 2023 No Comments READ MORE +

Which two steps are required for this migration and cutover?

You plan to use Foreign LUN Import (FLI) to migrate data from an older storage array to an ONTAP cluster. You have properly cabled the storage array and the NetApp nodes to your dual-fabric SAN. Which two steps are required for this migration and cutover? (Choose two.)A . Add NetApp...

May 11, 2023 No Comments READ MORE +

What caused the problem?

Exhibit: cl01::>igroup show Cvserver svm1 VserverIgroup Protocol OS Type Initiators --------- ------------- ------ -- --------- ----------------- -------------------- svm1 esx_cluster mixed vmware 20:00:00:25:b5:11:a0:01, 20:00:00:25:b5:11:b0:01, iqn.1998-01.com.vmware:esx02 cl01::> A customer is provisioning storage for two ESXi hosts using FCoE with CNA adapters. The customer mapped the LUN to the igroup shown in the...

May 11, 2023 No Comments READ MORE +

Which command provides information on Snapshot copy auto delete variables?

Which command provides information on Snapshot copy auto delete variables?A . -volume modify -space-mgmt-try-first autodelete- B.-volume snapshot autodelete show- C.-volume show- D.-volume file clone autodelete-View AnswerAnswer: B

May 11, 2023 No Comments READ MORE +

Which configuration must be made to achieve this requirement?

An administrator has expanded a 2-node ONTAP cluster to a 4-node ONTAP cluster. The cluster is using FC LUNs with all of the default settings. You must rebalance the LUNs to the new nodes. Which configuration must be made to achieve this requirement?A . The new nodes must be added...

May 11, 2023 No Comments READ MORE +

What is required to accomplish this task?

You must ensure that a cluster that uses FabricPool has high availability. What is required to accomplish this task?A . four cluster LIFs B.an IPspace that is dedicated to the FabricPool C.a local failover policy for intercluster LIFs D.a cloud bucketView AnswerAnswer: C

May 11, 2023 No Comments READ MORE +