To satisfy the Increased Ventilation strategy in the Indoor Environmental Quality Credit, Enhanced Indoor Air Quality Strategies, the breathing zone rates of outdoor air ventilation to all occupied spaces must be increased above the minimum rates required in ASHRAE 62.1-2010 by at least what percentage?
To satisfy the Increased Ventilation strategy in the Indoor Environmental Quality Credit, Enhanced Indoor Air Quality Strategies, the breathing zone rates of outdoor air ventilation to all occupied spaces must be increased above the minimum rates required in ASHRAE 62.1-2010 by at least what percentage?A . 10%B . 20%C ....
Discussing the project goals to help identify the credits and options that the team should attempt is an example of
Discussing the project goals to help identify the credits and options that the team should attempt is an example ofA . documenting LEED creditsB . creating the Basis of DesignC . developing the LEED ScorecardD . implementing the Commissioning PlanView AnswerAnswer: C Explanation: The process of discussing project goals to...
How can the LEED AP relieve the owner's concerns?
An owner has expressed concerns to the LEED AP about the costs associated with the integrative process. How can the LEED AP relieve the owner's concerns?A . The LEED AP should explain to the owner that since the integrative process is not a prerequisite, it can be dropped from the...
When developing the overall energy strategy of the project, which credit should the client consider to work synergistically with the Energy and Atmosphere Credit, Enhanced Commissioning, on an ongoing basis?
When developing the overall energy strategy of the project, which credit should the client consider to work synergistically with the Energy and Atmosphere Credit, Enhanced Commissioning, on an ongoing basis?A . Advanced Energy MeteringB . Renewable Energy ProductionC . Green Power and Carbon OffsetsD . Enhanced Refrigerant ManagementView AnswerAnswer: A...
A project team is pursuing certification for a medical clinic with 150 full time employees and 250 peak visitors. The project team is considering the Location and Transportation Credit for Bicycle Facilities. Providing which of the following is a minimum requirement to earn the credit?
A project team is pursuing certification for a medical clinic with 150 full time employees and 250 peak visitors. The project team is considering the Location and Transportation Credit for Bicycle Facilities. Providing which of the following is a minimum requirement to earn the credit?A . A bicycle maintenance program...
When evaluating a map of nearby diverse uses, which of the following would you recommend to be entered in the calculation?
The project team for a bank project located in a mall is wondering whether they can earn Location and Transportation Credit Surrounding Density and Diverse Uses, Option 2. Diverse Uses. When evaluating a map of nearby diverse uses, which of the following would you recommend to be entered in the...
Which of the following credits would be applicable?
A luxury hotel project is one point away from attaining LEED Platinum certification. The LEED AP is recommending that the team pursue Innovation Credit, Innovation, Option 3. Additional Strategies. Which of the following credits would be applicable?A . Regional Priority Credit, Optimize Energy PerformanceB . Indoor Environmental Quality Credit, Quality...
The project material costs for Building Product Disclosure and Optimization cost-based credits are
The project material costs for Building Product Disclosure and Optimization cost-based credits areA . actual costs, furniture includedB . default costs, 30% of total construction costC . actual costs, furniture optionalD . default costs, 40% of total construction costView AnswerAnswer: C Explanation: The costs considered for Building Product Disclosure and...
Which of the following building attributes will help the tenant achieve points in the Location and Transportation category?
A tenant with 1,000 employees wishes to pursue LEED Interior Design and Construction Certification for their space in which they will be the sole tenant. Which of the following building attributes will help the tenant achieve points in the Location and Transportation category?A . A car sharing programB . 60...
A project has performed an energy model which has resulted in the following energy end use consumption:
A project has performed an energy model which has resulted in the following energy end use consumption: To meet the requirements for Energy and Atmosphere Credit, Advanced Energy Metering, Option 2. Advanced Metering, energy meters must be installed for energy end uses inA . space cooling, interior fans and receptaclesB...