Which of the following could be considered diverted construction waste?

Which of the following could be considered diverted construction waste?A . Excavated soilB . Land-clearing debrisC . Alternative daily coverD . Asphalt with aggregateView AnswerAnswer: D Explanation: According to the LEED v4 Reference Guide for Building Design and Construction, diverted construction waste is defined as "materials that are diverted from...

March 10, 2024 No Comments READ MORE +

Which of the following project team members should be integrated early into the design phase to assist with earning the Materials and Resources Prerequisite, Construction and Demolition Waste Management Planning?

Which of the following project team members should be integrated early into the design phase to assist with earning the Materials and Resources Prerequisite, Construction and Demolition Waste Management Planning?A . OwnerB . ContractorC . OccupantsD . Facility managerView AnswerAnswer: B Explanation: Contractor The contractor is the project team member...

March 9, 2024 No Comments READ MORE +

What is the minimum number of members of the integrated project team for the Integrative Process Prerequisite, Integrative Project Planning and Design?

What is the minimum number of members of the integrated project team for the Integrative Process Prerequisite, Integrative Project Planning and Design?A . OneB . TwoC . FourD . SixView AnswerAnswer: C Explanation: According to the LEED Reference Guide for Building Design and Construction1, the Integrative Process Prerequisite, Integrative Project...

March 9, 2024 No Comments READ MORE +

Which of the following is the location of CO2 sensors in naturally ventilated spaces to comply with the Indoor Environmental Quality Prerequisite, Minimum Indoor Air Quality Performance?

Which of the following is the location of CO2 sensors in naturally ventilated spaces to comply with the Indoor Environmental Quality Prerequisite, Minimum Indoor Air Quality Performance?A . At least 6 ft. (2 m) above the floorB . At least 3 ft. (1 m) away from windowsC . Between 3...

March 9, 2024 No Comments READ MORE +

Which one of the following represents quality transit service as defined in Location and Transportation Credit, Access to Quality Transit?

Which one of the following represents quality transit service as defined in Location and Transportation Credit, Access to Quality Transit?A . A bus stop served by two bus lines Monday through Friday, located 1/8 mi. (0.20 km) from the project buildingB . A rail station served by one train line...

March 9, 2024 No Comments READ MORE +

Selecting a high-reflectance interior paint which is compliant with South Coast Air Quality Management District (SCAQMD) Rule 1113 can help contribute towards which two credits?

Selecting a high-reflectance interior paint which is compliant with South Coast Air Quality Management District (SCAQMD) Rule 1113 can help contribute towards which two credits?A . Indoor Environmental Quality Credit, Low-Emitting Materials and Indoor Environmental Quality Credit, Interior LightingB . Indoor Environmental Quality Credit, Low-Emitting Materials and Sustainable Sites Credit,...

March 9, 2024 No Comments READ MORE +

Which of the following materials on the documentation contribute towards the credit?

The contractor has submitted waste hauling reports for review in order to achieve Materials and Resources Credit, Construction and Demolition Waste Management. Which of the following materials on the documentation contribute towards the credit? A. Excavated soil B. Wood derived fuel C. Items sent to the local incinerator D. Alternate...

March 9, 2024 No Comments READ MORE +

A new commercial building is being designed to use small capacity air handling units. To meet the requirements of the Carbon Dioxide Monitoring strategy in the Indoor Environmental Quality Credit, Enhanced Indoor Environmental Quality Strategies, where would CO2 monitors need to be located?

A new commercial building is being designed to use small capacity air handling units. To meet the requirements of the Carbon Dioxide Monitoring strategy in the Indoor Environmental Quality Credit, Enhanced Indoor Environmental Quality Strategies, where would CO2 monitors need to be located?A . In each occupied spaceB . In...

March 9, 2024 No Comments READ MORE +

Which of the following projects is eligible to pursue the Energy and Atmosphere Prerequisite, Minimum Energy Performance, Option 2. Prescriptive Compliance: ASHRAE 50% Advanced Energy Design Guide?

Which of the following projects is eligible to pursue the Energy and Atmosphere Prerequisite, Minimum Energy Performance, Option 2. Prescriptive Compliance: ASHRAE 50% Advanced Energy Design Guide?A . 50,000 ft2 (4 645 m2) office projectB . 80,000 ft2 (7 432 m2) hospital projectC . 110,000 ft2 (10 219 m2) school...

March 9, 2024 No Comments READ MORE +

What can the project design team explain to the school district about how this strategy will affect the operational energy cost?

A school wants to incorporate natural daylighting in classrooms on all sides of the building. What can the project design team explain to the school district about how this strategy will affect the operational energy cost?A . Heat gain will reduce the air conditioning loadB . Having the lights off...

March 9, 2024 No Comments READ MORE +