For emergency treatment of business interruption, fault location should be carried out as soon as possible, and then the business should be restored.

For emergency treatment of business interruption, fault location should be carried out as soon as possible, and then the business should be restored.A . TRUEB . FALSEView AnswerAnswer: B

November 30, 2021 No Comments READ MORE +

The size of the crossover capacity of the NG SDH system is determined by the crossover single board, so the crossover capacity upgrade is completed by replacing the crossover board.

The size of the crossover capacity of the NG SDH system is determined by the crossover single board, so the crossover capacity upgrade is completed by replacing the crossover board.A . TRUEB . FALSEView AnswerAnswer: B

November 30, 2021 No Comments READ MORE +

Which layer of the TCP/UDP protocol is located in the TCP/IP protocol?

Which layer of the TCP/UDP protocol is located in the TCP/IP protocol?A . Application layerB . Network layerC . Data link layerD . Transport layerView AnswerAnswer: D

November 30, 2021 No Comments READ MORE +

Which of the following statements about the MPLS-TP OAM level is correct?  

Which of the following statements about the MPLS-TP OAM level is correct?  A . Section is the service layer of Tunnel, Tunnel is the service layer of PW, and PW is the service layer of ServiceB . Section is the service layer of PW, PW is the service layer of...

November 30, 2021 No Comments READ MORE +

The service signals that the HUNQ2 board cannot transmit are:

The service signals that the HUNQ2 board cannot transmit are:A . STM-16B . GEC . ODU3D . ODUflexView AnswerAnswer: C

November 29, 2021 No Comments READ MORE +

The following description about using the synchronization method to create optical fibers, which is wrong?

The following description about using the synchronization method to create optical fibers, which is wrong?A . There is no need to create an optical fiber with the same information on both the network management side and the network element side.B . If there are optical fibers that have not been...

November 29, 2021 No Comments READ MORE +

In OSN 1800, the LOA single board can implement the Ethernet Layer 2 scheduling function.

In OSN 1800, the LOA single board can implement the Ethernet Layer 2 scheduling function.A . TRUEB . FALSEView AnswerAnswer: B

November 29, 2021 No Comments READ MORE +

The key to NG WDM system fault location is to accurately locate the fault to a single station.

The key to NG WDM system fault location is to accurately locate the fault to a single station.A . TRUEB . FALSEView AnswerAnswer: A

November 29, 2021 No Comments READ MORE +

The maximum output optical power of an optical amplifier OBU is 20 dBm, and when it is used in the C-band 80 passive system, how much dBm should the single-wave standard output optical power be?

The maximum output optical power of an optical amplifier OBU is 20 dBm, and when it is used in the C-band 80 passive system, how much dBm should the single-wave standard output optical power be?A . +4dBmB . +7dBmC . -2dBmD . +1dBmView AnswerAnswer: D

November 29, 2021 No Comments READ MORE +