Which of the following descriptions of MPLS is incorrect? (Multiple choice)

Which of the following descriptions of MPLS is incorrect? (Multiple choice)A . MPLS: Multi-protocol Label Switching, a non-standardized routing and switching technology platform B. P/PE: P (Provider) is the internal node of the MPLS network, and PE (Provider Edge) is the edge of the MPLS network c. The operation of...

May 4, 2023 No Comments READ MORE +

OSN 3500 branch line business has strong up and down capabilities, with 16 branch line outlet slots, 504 2M, 32 E4, 117 E3/DS3, 132 STM-1e up and down subracks, providing STM-1/4/ 16/64 group rate.

OSN 3500 branch line business has strong up and down capabilities, with 16 branch line outlet slots, 504 2M, 32 E4, 117 E3/DS3, 132 STM-1e up and down subracks, providing STM-1/4/ 16/64 group rate.A . True B. FalseView AnswerAnswer: A

May 4, 2023 No Comments READ MORE +

For the OSN6800 device, which of the following slots does not have an electrical layer crossover backplane bus?

For the OSN6800 device, which of the following slots does not have an electrical layer crossover backplane bus?A . Slot1 B. SIot9 C. SIot10 D. SIot17View AnswerAnswer: D.

May 4, 2023 No Comments READ MORE +

Which of the following is the monitoring overhead for monitoring and reporting OTUk_DEG and OTUk_EXC alarms?

Which of the following is the monitoring overhead for monitoring and reporting OTUk_DEG and OTUk_EXC alarms?A . SM B.PM C. TCMiView AnswerAnswer: A

May 3, 2023 No Comments READ MORE +

The physical layer of LAN is often used for the interconnection of routers and switches. Although it is called a local area network, if a 10GBase-LR or -ER optical module is used, the transmission distance can reach 80 kilometers.

The physical layer of LAN is often used for the interconnection of routers and switches. Although it is called a local area network, if a 10GBase-LR or -ER optical module is used, the transmission distance can reach 80 kilometers.A . True B. FalseView AnswerAnswer: A

May 2, 2023 No Comments READ MORE +

The number of network elements (including REG) in the two -fiber bidirectional multiplex section sharing protection ring can exceed 16.

The number of network elements (including REG) in the two -fiber bidirectional multiplex section sharing protection ring can exceed 16.A . True B. FalseView AnswerAnswer: A

May 2, 2023 No Comments READ MORE +

Complex flow classification refers to classifying packets according to the ToS (Type of Service ) field of IP packets , user priority or EXP field of MPLS packets to identify traffic with different priority characteristics.

Complex flow classification refers to classifying packets according to the ToS (Type of Service ) field of IP packets , user priority or EXP field of MPLS packets to identify traffic with different priority characteristics.A . True B. FalseView AnswerAnswer: B

May 2, 2023 No Comments READ MORE +

Which of the following situations can cause the board to reinsert the BDI maintenance signal to the upstream site? (Multiple choice)

Which of the following situations can cause the board to reinsert the BDI maintenance signal to the upstream site? (Multiple choice)A . The board reports R_LOS B. Report OTU2_DEG on the board C. Report OTU2_LOF on the board D. ODU2_PM_LCKView AnswerAnswer: ACD

May 1, 2023 No Comments READ MORE +

TM is a terminal multiplexer. Its function is: the line port inputs/outputs one STM-N signal, and the branch port can output/input multiple low-speed branch signals.

TM is a terminal multiplexer. Its function is: the line port inputs/outputs one STM-N signal, and the branch port can output/input multiple low-speed branch signals.A . True B. FalseView AnswerAnswer: A

May 1, 2023 No Comments READ MORE +