Which of the typical configurations of FusionModule800 are optional?
Which of the typical configurations of FusionModule800 are optional?A . Temperature and humidity, door magnet, water immersion, smoke sensor, mobile phone APPB . Smoke sensor, door sensor, water flooding, SMS alarm, padC . Water immersion, door sensor, video, backup power, ibatteryView AnswerAnswer: B
The fans of NetCol5000-C030H row-level chilled water precision air conditioners can be maintained online, and a separate power-off switch can be provided for each fan to avoid safety hazards caused by direct live maintenance.
The fans of NetCol5000-C030H row-level chilled water precision air conditioners can be maintained online, and a separate power-off switch can be provided for each fan to avoid safety hazards caused by direct live maintenance.A . TrueB . FalseView AnswerAnswer: A
UPS5000-E has the function of adjustable battery number, which avoids the replacement of the entire battery group due to a single battery failure and solves the problem of difficult maintenance of traditional UPS batteries. How many adjustable batteries does UPS5000-E (50kVA module) support?
UPS5000-E has the function of adjustable battery number, which avoids the replacement of the entire battery group due to a single battery failure and solves the problem of difficult maintenance of traditional UPS batteries. How many adjustable batteries does UPS5000-E (50kVA module) support?A . 30-40B . 32-40C . 32-42D ....
Huawei precision air conditioners have RS485 communication interfaces for remote inspection and parameter setting of the system: Modbus open protocol is provided to access the computer room environment monitoring system to reduce service costs.
Huawei precision air conditioners have RS485 communication interfaces for remote inspection and parameter setting of the system: Modbus open protocol is provided to access the computer room environment monitoring system to reduce service costs.A . TrueB . FalseView AnswerAnswer: A
The NetEco management system supports reporting alarm information to third-party management systems through the SNMP interface.
The NetEco management system supports reporting alarm information to third-party management systems through the SNMP interface.A . TrueB . FalseView AnswerAnswer: A
FusionModule2000 integrated UPS has two models: 50K/125K.
FusionModule2000 integrated UPS has two models: 50K/125K.A . TrueB . FalseView AnswerAnswer: A
The power module efficiency of UPS5000-E (25-75kVA) is 96%.
The power module efficiency of UPS5000-E (25-75kVA) is 96%.A . TrueB . FalseView AnswerAnswer: A
The air conditioning water system includes the cooling water system, the chilled water system and the condensing water system.
The air conditioning water system includes the cooling water system, the chilled water system and the condensing water system.A . TrueB . FalseView AnswerAnswer: A
FusionModule500 & FusionModule800 can be equipped with emergency fans
FusionModule500 & FusionModule800 can be equipped with emergency fansA . TrueB . FalseView AnswerAnswer: B
Configure a modular redundant UPS system. As long as the number of modules meets the basic requirements, there is no need to consider the distribution of UPS modules on different racks.
Configure a modular redundant UPS system. As long as the number of modules meets the basic requirements, there is no need to consider the distribution of UPS modules on different racks.A . TrueB . FalseView AnswerAnswer: B