Regarding the integrated UPS5000-E120K-HASBS statements, which of the following is incorrect?

Regarding the integrated UPS5000-E120K-HASBS statements, which of the following is incorrect?A . Support intelligent battery management, the number of battery cells can be adjustedB . Support incoming lineC . ATS does not support manual switchingD . The power statistics interface can display the power of each output branchView AnswerAnswer: C

September 16, 2024 No Comments READ MORE +

The function of the SW button on the ECC800 is ( ).

The function of the SW button on the ECC800 is ( ).A . Restore default IP addressB . Wireless networking pairingC . Device software upgradeD . Clear the alarmView AnswerAnswer: B

September 16, 2024 No Comments READ MORE +

Which of the following components can control the lighting in the computer room and control the PAD charging?

Which of the following components can control the lighting in the computer room and control the PAD charging?A . Access Control ActuatorB . ActuatorC . Cabinet collectorD . Smart ETH socketView AnswerAnswer: B

September 14, 2024 No Comments READ MORE +

For storage batteries that have been stored for 18 months or more and have not been charged during the period, what should be dealt with?

For storage batteries that have been stored for 18 months or more and have not been charged during the period, what should be dealt with?A . No need to deal with, use as soon as possibleB . Need to supplement point processing, use it as soon as possibleC . Need...

September 12, 2024 No Comments READ MORE +

In ECO mode, when the input is stable, the UPS works in () state.

In ECO mode, when the input is stable, the UPS works in () state.A . Main circuit inverterB . Bypass c. batteryC . Maintenance BypassView AnswerAnswer: B

September 12, 2024 No Comments READ MORE +

The signal processing of the UPS5000-E will centralize control:

The signal processing of the UPS5000-E will centralize control:A . Energy Control Module ECMB . Power ModuleC . Bypass ModuleD . Maintenance Bypass ModuleView AnswerAnswer: A

September 10, 2024 No Comments READ MORE +

Modifying the micro-module layout view on ECC800 supports simultaneous editing by ( ) users.

Modifying the micro-module layout view on ECC800 supports simultaneous editing by ( ) users.A . 1B . 2C . 3D . 4View AnswerAnswer: A

September 10, 2024 No Comments READ MORE +

The straight pipe distance of NETCOL5000-C pipeline fixed title is ().

The straight pipe distance of NETCOL5000-C pipeline fixed title is ().A . 3200MMB . 3000MMC . 2600MMD . 2500MMView AnswerAnswer: D

September 10, 2024 No Comments READ MORE +

When a fire occurs in the box, ( ) is used to start the gas fire extinguishing device in an emergency.

When a fire occurs in the box, ( ) is used to start the gas fire extinguishing device in an emergency.A . Emergency stop button/manual deflation buttonB . Fire CylindersC . Pressure switchD . Solenoid valveView AnswerAnswer: A

September 9, 2024 No Comments READ MORE +

The terminal power of the battery in the open circuit state is called ().

The terminal power of the battery in the open circuit state is called ().A . Rated voltageB . Discharge voltageC . Open-circuit voltageD . Actual voltageView AnswerAnswer: C

September 9, 2024 No Comments READ MORE +