Which is not part of the routine maintenance item of the ECC800 power module?

Which is not part of the routine maintenance item of the ECC800 power module?A . Check if the power indicator light is normalB . Check the ECC800 module fanC . Check whether the power wiring is looseD . Create a micromodule plan viewView AnswerAnswer: D

September 20, 2024 No Comments READ MORE +

The principle of the ( ) humidifier is that the high infrared light makes the water surface release water vapor and diffuse into the airflow that needs to be humidified.

The principle of the ( ) humidifier is that the high infrared light makes the water surface release water vapor and diffuse into the airflow that needs to be humidified.A . ElectrodesB . HumidityC . High pressure sprayD . InfraredView AnswerAnswer: D

September 20, 2024 No Comments READ MORE +

The user can log in to the WEB interface of ( ) to view the operating status of the device in the micro-module.

The user can log in to the WEB interface of ( ) to view the operating status of the device in the micro-module.A . Water Immersion SensorB . ECC800C . Cabinet electronic lockD . Sound and light alarmView AnswerAnswer: B

September 19, 2024 No Comments READ MORE +

On the NETECO interface, a module can only bind () ECC800 devices.

On the NETECO interface, a module can only bind () ECC800 devices.A . 1B . 2C . 3D . 4View AnswerAnswer: A

September 19, 2024 No Comments READ MORE +

NETCOL5000-C temperature and humidity sensor dial-code setting error may cause:

NETCOL5000-C temperature and humidity sensor dial-code setting error may cause:A . Water leakage at the bottom of the deviceB . The return air temperature or fan speed fluctuates greatlyC . The drainage capacity of the equipment is significantly reducedD . The temperature and humidity sensor cannot detect the temperature and...

September 19, 2024 No Comments READ MORE +

When the outdoor units of Huawei air-cooled air conditioners are installed horizontally, the distance between the two outdoor units is ≥ () MM.

When the outdoor units of Huawei air-cooled air conditioners are installed horizontally, the distance between the two outdoor units is ≥ () MM.A . 400B . 800C . 1200D . 2000View AnswerAnswer: C

September 18, 2024 No Comments READ MORE +

In the battery model 6-GFM-150, the 150 mark is the ( ) of the battery.

In the battery model 6-GFM-150, the 150 mark is the ( ) of the battery.A . actual capacityB . rated capacityC . maximum capacity                     D . minimum capacityView AnswerAnswer: B

September 18, 2024 No Comments READ MORE +

The multi-function sensor in the modular channel of Fusion Module2000 can be connected to the () component.

The multi-function sensor in the modular channel of Fusion Module2000 can be connected to the () component.A . Cabinet collectorB . WIFI converterC . Only ETH socketD . Access Control ActuatorView AnswerAnswer: C

September 17, 2024 No Comments READ MORE +

Which of the following air supply methods must have a reasonable raised floor height?

Which of the following air supply methods must have a reasonable raised floor height?A . Air supply from the upper hoodB . Underfloor air supplyC . Upper air duct supplyD . Row-level horizontal air supplyView AnswerAnswer: B

September 17, 2024 No Comments READ MORE +

When the Huawei air-cooled air-conditioning compressor is turned on for the first time, the crankcase heating belt needs to be preheated for more than () hours.

When the Huawei air-cooled air-conditioning compressor is turned on for the first time, the crankcase heating belt needs to be preheated for more than () hours.A . 2B . 6C . 12D . 24View AnswerAnswer: C

September 16, 2024 No Comments READ MORE +