How long before a license expires will UnityVSA send the first alert warning?
How long before a license expires will UnityVSA send the first alert warning?A . 3 daysB . 7 daysC . 15 daysD . 1 monthView AnswerAnswer: D Explanation: As a reminder, UnityVSA displays several alerts in Unisphere prior to the license expiration date. The table below shows when alerts are...
Which drive types can be configured to meet the administrator’s requirements?
A storage administrator is implementing FAST Cache on a Unity 500 storage array and can select from a mix of SSD drives. Which drive types can be configured to meet the administrator’s requirements?A . 200 GB and 400 GBB . 400GB and 1.6 TBC . 1.6 TB and 3.2 TBD...
How can the service provider set a static IP address for the Unity storage system management interface?
A service provider is installing a Unity storage system for an end-user. The end-user is concerned about network security and will not allow the service provider access to the network. How can the service provider set a static IP address for the Unity storage system management interface?A . Use the...
Which severity level alerts for a fault condition that has occurred, has minor impact on the system, and does not need to be fixed immediately?
Which severity level alerts for a fault condition that has occurred, has minor impact on the system, and does not need to be fixed immediately?A . CriticalB . NoticeC . ErrorD . WarningView AnswerAnswer: D Explanation: Event Severity levels are: critical, error, warning, info.
What describes multiple LUN snapshots?
What describes multiple LUN snapshots?A . Captures multiple point-in-time data states.Snapshot data state is marked “unmodified” from its source when attached.Snapshot tree supports multiple simultaneous attaches.B . Captures multiple point-in-time data states.Snapshot data state is marked “unmodified” from its source when attached.Snapshot tree supports only one attach at a time.C...
When deploying virtual disks for a UnityVSA system, what is an EMC recommended Disk Provision Policy?
When deploying virtual disks for a UnityVSA system, what is an EMC recommended Disk Provision Policy?A . Thick Provision Eager ZeroedB . Thin ProvisionC . Thick ProvisionD . Thick Provision Lazy ZeroedView AnswerAnswer: A Explanation: EMC recommends the following settings for all virtual disks:
Which file extension is used for Unity license files?
A system administrator is browsing their local management station for a Unity license file. Which file extension is used for Unity license files?A . .licB . .rsaC . .linD . .cerView AnswerAnswer: A Explanation: You need to obtain the license file (.lic) from the EMC license management web site. References:...
When the LUN Snapshot Attach to Host operation is performed, what does the Unity system optionally do before beginning the attach process?
When the LUN Snapshot Attach to Host operation is performed, what does the Unity system optionally do before beginning the attach process?A . Creates a snapshot of the LUNB . Detaches the host from the snapshots of any other LUNC . Creates a copy of the snapshotD . Deletes all...
Which single block migration option will work for both the virtual and hardware storage devices?
A system administrator has added a new Unity storage array to their environment. The administrator wants to migrate block data from vVNX running in their VMware environment to a UnityVSA. In addition, the administrator needs to migrate the block data from an older CLARiiON storage array to the new Unity...
Which operation can be performed from the FAST VP settings section in the Unisphere Settings window?
Which operation can be performed from the FAST VP settings section in the Unisphere Settings window?A . Enable scheduled data relocation at the pool levelB . Exclude pool from the data relocation scheduleC . Enable scheduled data relocation at the system levelD . View the data relocation progress between tiersView...