Which configuration steps are needed?

A storage administrator wants to add as asynchronous replication session to a pair of Unity systems with an existing synchronous replication session that is operating correctly. Which configuration steps are needed?A . Create Replication interfaces on both systems. Modify the Replication Connection Mode. Run a Replication Connection Verify and Update...

May 23, 2020 No Comments READ MORE +

Which Fibre Channel port on each SP must be used for native synchronous replication?

An administrator’s Unity system is configured with both a Fibre Channel CNA and a Fibre Channel I/O module. Which Fibre Channel port on each SP must be used for native synchronous replication?A . CNA FC port 5B . I/O module FC port 2C . CNA FC port 4D . I/O...

May 23, 2020 No Comments READ MORE +

How can the IP address be changed?

A system administrator has configured a system using the Initial Configuration wizard. After completing the wizard, the administrator discovers that an incorrect IP address has been assigned to the Unity system. How can the IP address be changed?A . The IP address cannot be changed once it has been configuredB...

May 23, 2020 No Comments READ MORE +

Which drive types can be configured to meet the administrator’s requirements?

A storage administrator is implementing FAST Cache on a Unity 500 storage array and can select from a mix of SSD drives. Which drive types can be configured to meet the administrator’s requirements?A . 200 GB and 400 GBB . 400GB and 1.6 TBC . 1.6 TB and 3.2 TBD...

May 22, 2020 No Comments READ MORE +

To meet the administrator's requirement without over provisioning the capacity, which Unity Hybrid storage array is recommended?

A storage administrator has requested a recommendation on upgrading their VNX5600 to a comparable Unity storage array. The solution requires a maximum capacity of 3.5 PB. To meet the administrator's requirement without over provisioning the capacity, which Unity Hybrid storage array is recommended?A . Unity 300B . Unity 400C ....

May 22, 2020 No Comments READ MORE +

What is one method that is used to verify an ESRS configuration?

What is one method that is used to verify an ESRS configuration?A . Proxy server authenticationB . RSA authenticationC . Trigger an SNMP trap testD . Send an e-mail verificationView AnswerAnswer: B Explanation: References: https://www.emc.com/collateral/software/data-sheet/h1948-secure-remote-supp-gateway­ds.pdf

May 22, 2020 No Comments READ MORE +

Which file extension is used for Unity license files?

A system administrator is browsing their local management station for a Unity license file. Which file extension is used for Unity license files?A . .licB . .rsaC . .linD . .cerView AnswerAnswer: A Explanation: You need to obtain the license file (.lic) from the EMC license management web site. References:...

May 22, 2020 No Comments READ MORE +

Which Unity service task is used to reinstall the root operating system while leaving the user’s data intact?

Which Unity service task is used to reinstall the root operating system while leaving the user’s data intact?A . Restore the Management serverB . Reimage the Storage ProcessorC . Restore the Management softwareD . Reinitialize the storage systemView AnswerAnswer: B Explanation: Re-image a storage processor (SP) to safely fix problems...

May 22, 2020 No Comments READ MORE +

Which in-place upgrade is required?

A company has a Unity 300 system with 200 SAS drives. They need to increase the number of SAS drives by 300. Which in-place upgrade is required?A . Unity 400FB . Unity 400C . Unity 600FD . Unity 500View AnswerAnswer: D Explanation: References: https://www.emc.com/collateral/data-sheet/h14958-unity-hybrid-family-ss.pdf?isKoreaPage=false&domainUrlForCanonical=https%3A%2F%2Fwww.emc.com

May 22, 2020 No Comments READ MORE +

When deploying virtual disks for a UnityVSA system, what is an EMC recommended Disk Provision Policy?

When deploying virtual disks for a UnityVSA system, what is an EMC recommended Disk Provision Policy?A . Thick Provision Eager ZeroedB . Thin ProvisionC . Thick ProvisionD . Thick Provision Lazy ZeroedView AnswerAnswer: A Explanation: EMC recommends the following settings for all virtual disks: - Disk Provisioning: Thick Provision Eager...

May 21, 2020 No Comments READ MORE +