Which segment size(s) is used by EMC Data Domain SISL?

Which segment size(s) is used by EMC Data Domain SISL?A . 4 - 12 KBB . 16 - 32 KBC . 24 and 44 KBD . 128 KBView AnswerAnswer: A

November 12, 2020 No Comments READ MORE +

Which hardware and capacity license options are available for an EMC Data Domain system?

Which hardware and capacity license options are available for an EMC Data Domain system?A . Expanded-Storage, Capacity-Active, DD Extended Retention, and Capacity-ArchiveB . Expanded-Storage, DD Extended Retention, Capacity-Active, Global Deduplication, and Capacity-ArchiveC . Expanded-Storage, Capacity-Active, Gateway, and Capacity-ArchiveD . Expanded-Storage, Global Compression, and DD Extended RetentionView AnswerAnswer: A

November 12, 2020 No Comments READ MORE +

In an EMC Data Domain environment, when are cage nuts used?

In an EMC Data Domain environment, when are cage nuts used?A . Square hole rack fasteningB . Rack-to-rack fasteningC . Round hole rack fasteningD . Tapped hole rack fasteningView AnswerAnswer: A

November 12, 2020 No Comments READ MORE +

What can an optional PCI-x Card slot be used for on an EMC Data Domain system?

What can an optional PCI-x Card slot be used for on an EMC Data Domain system?A . 1 GbE, 10 GbE, HBA VTL, SAS HBA onlyB . 1 GbE, 10 GbE, SAS HBA onlyC . 1 GbE and SAS HBA onlyD . 1 GbE, 10 GbE, HBA VTL onlyView AnswerAnswer:...

November 12, 2020 No Comments READ MORE +

What are the states of the SAS LED connection status indicators at the back of an EMC Data Domain ES20?

What are the states of the SAS LED connection status indicators at the back of an EMC Data Domain ES20?A . White, flashing green, solid green, amberB . Red, flashing green, solid green, amberC . White, solid green, flashing amberD . Flashing red, flashing green, solid green, amberView AnswerAnswer: A

November 11, 2020 No Comments READ MORE +

What is the name of the dedicated IPMI management Ethernet port on an EMC Data Domain system?

What is the name of the dedicated IPMI management Ethernet port on an EMC Data Domain system?A . bmc0aB . bmc-eth01C . bmc-eth02D . bmc-eth0aView AnswerAnswer: A

November 11, 2020 No Comments READ MORE +

Which Data Domain software licenses need to be applied to the system?

Data exposure must be minimized when disk-based hardware is shipped. Which Data Domain software licenses need to be applied to the system?A . Retention Lock and EncryptionB . Encryption and VTL with NDMPC . DD Boost and EncryptionD . Retention Lock and ReplicationView AnswerAnswer: A

November 10, 2020 No Comments READ MORE +

When connecting a single expansion shelf to a EMC Data Doman controller, what are the recommended SAS ports that should be used?

Refer to the Exhibit. When connecting a single expansion shelf to a EMC Data Doman controller, what are the recommended SAS ports that should be used?A . 3a and 2aB . 3a and 2bC . 3b and 2aD . 3b and 2bView AnswerAnswer: B

November 10, 2020 No Comments READ MORE +

Which protocols are supported with EMC Data Domain Extended Retention?

Which protocols are supported with EMC Data Domain Extended Retention?A . CIFS, NFS, VTL, DD BoostB . NFS, DD Boost, NDMPC . VTL, NDMP, CIFS, NFSD . DD Boost, NFS, CIFS, iSCSIView AnswerAnswer: A

November 10, 2020 No Comments READ MORE +

When cabling the controller to the shelves, where does the host port on the last shelf in the chain get connected?

You are installing an EMC Data Domain system with two expansion shelves in a customer-provided rack. When cabling the controller to the shelves, where does the host port on the last shelf in the chain get connected?A . Expansion port of the upstream shelfB . Expansion port of the controllerC...

November 10, 2020 No Comments READ MORE +