What are the vSAN storage policy settings applied to the VxRail Manager VM during initial setup*?

What are the vSAN storage policy settings applied to the VxRail Manager VM during initial setup*?A . Primary level of failures to tolerate = 1 Failure tolerance method = Erasure coding Object space reservation (%) = 100B . Primary level of failures to tolerate = 1 Object space reservation (%)...

August 14, 2020 No Comments READ MORE +

How much additional rack space is required to accommodate the new nodes?

A user has three G Series nodes in a VxRail cluster They are planning to add five additional G Series nodes How much additional rack space is required to accommodate the new nodes?A . 1UB . 2UC . 5UD . 10UView AnswerAnswer: B

August 12, 2020 No Comments READ MORE +

You are planning to install CloudArray Virtual Edition Where should you navigate to in VxRail Manager?

You are planning to install CloudArray Virtual Edition Where should you navigate to in VxRail Manager?A . Config > SystemB . Config > GeneralC . Support > DownloadD . Config > MarketView AnswerAnswer: D

August 12, 2020 No Comments READ MORE +

Which action must the administrator perform to use this feature?

A VxRail administrator wants to search for VxRail related knowledge base articles through the VxRail Manager user interface Which action must the administrator perform to use this feature?A . Register for a VxRail Community login and set the credentials in VxRail ManagerB . Work with Dell EMC to register the...

August 11, 2020 No Comments READ MORE +

How much more vSAN capacity is consumed in Cluster-B than in Cluster-A?

An environment has two VxRail clusters with the following hardware configuration: - Cluster-A is using FTT = 2 and FTM = Erasure Coding - Cluster-B is using FTT = 2 and FTM = Mirroring A 100 GB VM is planned to be vMotioned from Cluster-A to Cluster-B How much more...

August 11, 2020 No Comments READ MORE +

What is the minimum number of nodes needed for self-healing after a failure with a vSAN storage policy of FTT = 1 and FTM = Mirroring?

What is the minimum number of nodes needed for self-healing after a failure with a vSAN storage policy of FTT = 1 and FTM = Mirroring?A . 3B . 4C . 5D . 6View AnswerAnswer: C

September 23, 2019 No Comments READ MORE +

When using a vSAN storage policy with FTT = 1 and FTM = Mirroring, how many witness components exist for a VMDK?

When using a vSAN storage policy with FTT = 1 and FTM = Mirroring, how many witness components exist for a VMDK?A . 0B . 1C . 2D . 3View AnswerAnswer: A

September 21, 2019 No Comments READ MORE +

What is the limit of locally cached managed storage included in the CloudArray Virtual Edition license packaged with a VxRail system?

What is the limit of locally cached managed storage included in the CloudArray Virtual Edition license packaged with a VxRail system?A . 1TBB . 5 TBC . 10 TBD . 15 TBView AnswerAnswer: A

September 20, 2019 No Comments READ MORE +

How many RecoverPoint for Virtual Machines licenses are included, per VxRail V Series node?

How many RecoverPoint for Virtual Machines licenses are included, per VxRail V Series node?A . 1B . 4C . 5D . 15View AnswerAnswer: D

September 18, 2019 No Comments READ MORE +

Where could you locate this information in the vSphere Web Client?

As a VxRail administrator, you must determine how long the rebuild will take after experiencing a hardware failure in the cluster. Where could you locate this information in the vSphere Web Client?A . Monitor > vSAN > Physical DisksB . Monitor > vSAN > Resyncing ComponentsC . Monitor > vSAN...

September 18, 2019 No Comments READ MORE +