What is a valid NIC selection on an All-Flash G Series Cluster in the VxRail First Run Wizard?

What is a valid NIC selection on an All-Flash G Series Cluster in the VxRail First Run Wizard?A . 2×10 GbE SFP+B . 2×25 GbE SFF28C . 2×10 GbE RJ45D . 4×1 GbE RJ45View AnswerAnswer: A

August 20, 2020 No Comments READ MORE +

How many nodes can be added simultaneously to an easting VxRail Cluster?

How many nodes can be added simultaneously to an easting VxRail Cluster?A . 1B . 2C . 4D . 6View AnswerAnswer: D

August 20, 2020 No Comments READ MORE +

Based on the required usable capacity, what should be the planned capacity of the design?

A VxRail Stretched Cluster will be configured with four All-Flash nodes at each site based on the following requirements: - PFTT=1 - SFTT=1 - FTM=Erasure Coding Based on the required usable capacity, what should be the planned capacity of the design?A . Single Site Capacity=200% Total Cluster Capacity=400%B . Single...

August 20, 2020 No Comments READ MORE +

How long does it take for the Primary node to be selected for a VxRail deployment after all nodes have been powered on?

How long does it take for the Primary node to be selected for a VxRail deployment after all nodes have been powered on?A . 15 to 20 secondsB . 5 to 10 minutesC . 5 to 10 secondsD . 15 to 20 minutesView AnswerAnswer: D

August 20, 2020 No Comments READ MORE +

Which VxRail model is the best option for them?

A customer. new to HCl and VxRail, has a Microsoft SharePoint workload that they would like to use as their main application. Which VxRail model is the best option for them?A . S SeriesB . G SeriesC . P SeriesD . E SeriesView AnswerAnswer: A

August 20, 2020 No Comments READ MORE +

What is the recommended course of action?

SRS does not appear to be configured properly for a given VxRail Appliance From vCenter you note that the current Dell EMC Secure Remote Services status appears to be enabled and connected. The customer maintains that the configuration is not correct. What is the recommended course of action?A . Disable...

August 20, 2020 No Comments READ MORE +

What command is used to restart the Loudmouth process on a VxRail node?

What command is used to restart the Loudmouth process on a VxRail node?A . /usr/lib/vmware/loudmouth/bin/loudmouth restartB . systemctl restart loudmouthC . systemctl restart vmware-loudmouthD . /etc/init.d/loudmouth restartView AnswerAnswer: A

August 19, 2020 No Comments READ MORE +

Which service determines the primary node after powering on Dell PowerEdge-based VxRail nodes during the deployment of a VxRail Appliance?

Which service determines the primary node after powering on Dell PowerEdge-based VxRail nodes during the deployment of a VxRail Appliance?A . MarvinB . ElectionC . PTAgentD . LoudmouthView AnswerAnswer: D

August 19, 2020 No Comments READ MORE +

How many RP4VM licenses is the customer entitled to?

A customer has three VxRail E560 nodes that have just been installed. How many RP4VM licenses is the customer entitled to?A . 5B . 10C . 15D . 20View AnswerAnswer: C

August 19, 2020 No Comments READ MORE +

What is the reason for this issue?

A VxRail deployment has just been completed. The vSAN backend IOPS metrics are not available for the Cluster. What is the reason for this issue?A . Data has not been populatedB . Health service has not be turned onC . VSAN storage policy has not been assignedD . Performance Service...

August 19, 2020 No Comments READ MORE +