In an SC Series environment, which Fibre Channel zoning method is more flexible?

In an SC Series environment, which Fibre Channel zoning method is more flexible?A . PortB . Single Initiator/Multi-TargetC . Single Initiator/Single TargetD . WWNView AnswerAnswer: D

April 3, 2020 No Comments READ MORE +

When performing the initial configuration on an SC9000 through the serial port, which command is used to reboot the controller?

When performing the initial configuration on an SC9000 through the serial port, which command is used to reboot the controller?A . qle factoryreset 5 0B . cs purge allC . -resetD . -restartView AnswerAnswer: A

April 3, 2020 No Comments READ MORE +

Which commands should be used to complete this task?

You need to set up the iDRAC IP address on an SC Series controller with the following details: - IP address 192.168.0.160 - subnet mask 255.255.255.0 - gateway 192.168.0.1 Which commands should be used to complete this task?A . ifconfig inet set eth0 ip 192.168.0.160 ifconfig inet set eth0 netmask...

April 3, 2020 No Comments READ MORE +

What is the maximum number of days in which array information can be retained?

You are testing a new SC7020 storage array. You decided to deploy a temporary installation of Dell Storage Manager (DSM) Data Collector with an embedded database. What is the maximum number of days in which array information can be retained?A . 15 daysB . 30 daysC . 60 daysD ....

April 3, 2020 No Comments READ MORE +

Which redundancy level can be selected to provide the maximum amount of storage?

When installing an SC Series array, the customer indicated that they want the controller configured to provide the maximum amount of storage space. You discover that the storage controller was shipped with twelve 900 GB drives and twelve 1.8 TB drives of the same type. Which redundancy level can be...

April 3, 2020 No Comments READ MORE +

Which zones accurately describe the zoning requirement for replication connectivity to be established when the source array is in Legacy Port Mode and the target array is in Virtual Port Mode?

Which zones accurately describe the zoning requirement for replication connectivity to be established when the source array is in Legacy Port Mode and the target array is in Virtual Port Mode?A . Zone 1 = All Source Virtual Port WWNs + All Remote Physical Port WWNs Zone 2 = All...

April 3, 2020 No Comments READ MORE +

What is a requirement for installing the Dell Storage Manager (DSM) Virtual Appliance?

What is a requirement for installing the Dell Storage Manager (DSM) Virtual Appliance?A . Must be installed on a standalone ESXi HypervisorB . Must be installed on a vVols datastoreC . Must be installed on a standalone Hyper-V HypervisorD . Must be installed on a standard datastoreView AnswerAnswer: D

April 2, 2020 No Comments READ MORE +

Which operating system runs the Dell Storage Manager (DSM) as a virtual appliance?

Which operating system runs the Dell Storage Manager (DSM) as a virtual appliance?A . CentOS 7B . Windows Server 2012 R2C . VMwareD . Windows Server 2010 R2View AnswerAnswer: C

April 2, 2020 No Comments READ MORE +

What is the minimum number of port(s), per switch, that can be used by each controller?

You are implementing a front-end connection in Legacy Port Mode on an SC4020 in a SAN with two iSCSI switches. What is the minimum number of port(s), per switch, that can be used by each controller?A . One port on each Ethernet switchB . Two ports on each Ethernet switchC...

January 10, 2020 No Comments READ MORE +

What is the maximum memory supported on a single SC9000 controller?

What is the maximum memory supported on a single SC9000 controller?A . 64 GBB . 96 GBC . 128 GBD . 256 GBView AnswerAnswer: D Explanation: Reference: https://www.dell.com/en-us/work/shop/povw/storage-sc9000

January 10, 2020 No Comments READ MORE +