In an Isilon Gen 5 environment, what is the maximum number of data stripes for the N+3d:1n1d protection level?

In an Isilon Gen 5 environment, what is the maximum number of data stripes for the N+3d:1n1d protection level?A . 15B . 16C . 18D . 20View AnswerAnswer: B Explanation: Reference: https://community.emc.com/community/products/isilon/blog/2018/01/17/storage-efficiency­protection-overhead-vs-usable-capacity

February 1, 2020 No Comments READ MORE +

What should be considered?

A company has a 4-node Isilon H600 cluster dedicated for a high-performance workflow. The administrator wants to convert their cluster SSD strategy from L3 cache to use the SSDs for metadata acceleration. What should be considered?A . Migration of data and metadata from the SSDs to HDDs can take hours.B...

February 1, 2020 No Comments READ MORE +

What is the recommended number of delegations for a SmartConnect zone name for each SmarConnect zone alias on a cluster?

What is the recommended number of delegations for a SmartConnect zone name for each SmarConnect zone alias on a cluster?A . 1B . 2C . 3D . 4View AnswerAnswer: D

January 31, 2020 No Comments READ MORE +

What is the client behavior when accessing the export?

An NFS export is created on the Isilon cluster. No clients are listed in the export rules. What is the client behavior when accessing the export?A . All clients on the network can access the export.B . No clients on the network can access the export.C . Clients can access...

January 28, 2020 No Comments READ MORE +

What is a possible reason for this behavior?

A company deployed an Isilon cluster that consists of eight nodes connected to a main production subnet by all available 10GB ports. Later, the company decided to implement a disaster recovery solution with a separate replication subnet. During the reconfiguration, one of the 10Gb ports from each of the nodes...

January 28, 2020 No Comments READ MORE +

What is the minimum number of additional switches required to support the configuration?

A company has an existing 8-node F800 Isilon cluster with two Z9100 Dell Ethernet back-end switches running on OneFS 8.2.0. The company is planning to add 72 A200 nodes into the cluster. What is the minimum number of additional switches required to support the configuration?A . 2B . 3C ....

January 28, 2020 No Comments READ MORE +

How many drives will be used across the disk pool to protect a 1 MB file?

An Isilon cluster has four H500 nodes. Data protection and access are set to N+1 and concurrency respectively. How many drives will be used across the disk pool to protect a 1 MB file?A . 4B . 8C . 10D . 11View AnswerAnswer: A

January 24, 2020 No Comments READ MORE +

In an Isilon environment, what is a requirement to join multiple, untrusted Active Directory (AD) authentication sources to an access zone?

In an Isilon environment, what is a requirement to join multiple, untrusted Active Directory (AD) authentication sources to an access zone?A . Must use a common /ifs tree for all access zones.B . Only one of the AD provider instances can exist in a zone at one time.C . All...

January 21, 2020 No Comments READ MORE +

Which action can be taken to resolve the capacity issue while new nodes are being delivered?

A company’s Isilon cluster has reached the capacity limit. The cluster consists of eight H500 nodes in a single node pool. Which action can be taken to resolve the capacity issue while new nodes are being delivered?A . Activate SmartPoolsB . Enable GNAC . Enable SpilloverD . Release VHS drivesView...

January 20, 2020 No Comments READ MORE +

When reviewing the actual protection output of N+4/2, what does the number “4” represent?

When reviewing the actual protection output of N+4/2, what does the number “4” represent?A . FEC stripe units per stripeB . Hard drives used per stripeC . Volume stripes per file systemD . FEC stripe units per file systemView AnswerAnswer: A Explanation: It's OneFS FEC protection nomenclature for our "hybrid"...

January 20, 2020 No Comments READ MORE +