What is the maximum supported latency for a VPLEX Metro implementation?
What is the maximum supported latency for a VPLEX Metro implementation?A . 2 msB . 50 msC . 5 msD . 15 msView AnswerAnswer: C
You need to claim storage that is presented to VPLEX from a VNX. What is required in order to create the mapping file needed by the VPLEX Claim Storage Wizard?
You need to claim storage that is presented to VPLEX from a VNX. What is required in order to create the mapping file needed by the VPLEX Claim Storage Wizard?A . A host with solutions enabler installed and zoned to SPA and SPBB . The user name, password and management...
You are configuring an FC Switch for a VPLEX implementation using VS2 engines. What is the required speed setting for the switch ports connected to the VPLEX FE ports in order to achieve the maximum throughput of VS2 engines?
You are configuring an FC Switch for a VPLEX implementation using VS2 engines. What is the required speed setting for the switch ports connected to the VPLEX FE ports in order to achieve the maximum throughput of VS2 engines?A . 8 GbpsB . 4 GbpsC . 16 GbpsD . 10...
How many WAN-COM zones will need to be created?
You are preparing a site for a large Metro VPLEX cluster. The storage administrator wants to prepare the storage network configuration and needs to ensure easy troubleshooting of storage path faults. How many WAN-COM zones will need to be created?A . 24B . 16C . 8D . 32View AnswerAnswer: D
During the installation of a small VPLEX Metro, the command ‘configuration continue-systemsetup’ is issued. What is accomplished by this command?
During the installation of a small VPLEX Metro, the command ‘configuration continue-systemsetup’ is issued. What is accomplished by this command?A . Back-end array discoveryB . Host initiator discoveryC . Second cluster initial setupD . Witness configurationView AnswerAnswer: A
How many directors in the cluster must be zoned and masked to these LUNs?
You are zoning a dual-engine Local VPLEX cluster to a Symmetrix array to see LUNs 0010 and 0020 for metadata backups. How many directors in the cluster must be zoned and masked to these LUNs?A . All of the directorsB . Any two directorsC . One from each engineD ....
Which volume allows for future incremental re-synchronization with the remote mirror once the link is restored?
A customer has a VPLEX Metro configuration across two data centers 200 km apart. During an overnight backup, the WAN-COM link between the two data centers fails. Which volume allows for future incremental re-synchronization with the remote mirror once the link is restored?A . Logging VolumeB . Storage VolumeC ....
You are preparing to migrate the topology of an installed VPLEX Local system. What is a supported upgrade path?
You are preparing to migrate the topology of an installed VPLEX Local system. What is a supported upgrade path?A . Local to Geo to GlobalB . Local to MetroC . Local to GlobalD . Local to Metro to GeoView AnswerAnswer: B
What is required of an ESX host for the Witness to be installed?
What is required of an ESX host for the Witness to be installed?A . Promiscuous mode set to AcceptB . ESX host in Cluster 1 failure domainC . MAC address change set to AcceptD . ESX host in Cluster 2 failure domainView AnswerAnswer: C
A customer has purchased a dual engine VPLEX Metro cluster. During installation, there are not enough free SAN ports to connect all WAN-COM ports to the SAN. What is the recommended approach?
A customer has purchased a dual engine VPLEX Metro cluster. During installation, there are not enough free SAN ports to connect all WAN-COM ports to the SAN. What is the recommended approach?A . The customer must connect the WAN-COM ports of the first engine only and disable the second engine...