Which product(s) support(s) only 7+1 in RAID 5 configurations?
Which product(s) support(s) only 7+1 in RAID 5 configurations?A . VMAX All Flash and PowerMax 8000B . VMAX All FlashC . VMAX3D . VMAX All Flash and PowerMax 2000View AnswerAnswer: B
What does a service level define?
What does a service level define?A . Expected average response time target for a Storage GroupB . Expected average response time target for a disk groupC . Expected average throughput for a Storage GroupD . Expected average throughput for a disk groupView AnswerAnswer: A
What is the correct sequence of steps to obtain PowerMax licenses and ensure the PowerMax is configured to allow the licensed features to work properly?
What is the correct sequence of steps to obtain PowerMax licenses and ensure the PowerMax is configured to allow the licensed features to work properly? View AnswerAnswer:
Where are VMAX3 SRDF/A Delta Set Extension (DSE) allocations stored?
Where are VMAX3 SRDF/A Delta Set Extension (DSE) allocations stored?A . CacheB . Fastest disk poolC . Default SRPD . DSE poolView AnswerAnswer: C
Which Unisphere for VMAX feature helps determine if a storage provisioning request can be met by the VMAX3 array with regards to SLO compliance?
Which Unisphere for VMAX feature helps determine if a storage provisioning request can be met by the VMAX3 array with regards to SLO compliance?A . Suitability CheckB . HeadroomC . FAST Array AdvisorD . SizerView AnswerAnswer: A
What is the function of Fabric SIB ports?
Refer to the Graphic. What is the function of Fabric SIB ports?A . EF emulation support for IBM mainframesB . Engine interconnectC . FC ISL to the core fabric switchD . FC/iSCSI NAS back-end fabric connectivityView AnswerAnswer: B
When implementing SRDF/Metro with Array Witness, what is a requirement of the witness array?
When implementing SRDF/Metro with Array Witness, what is a requirement of the witness array?A . vApp running on a VMware ESXi serverB . Empty RDF group from witness to source and targetC . Two RDF groups with source and target devicesD . Minimum of two witness arraysView AnswerAnswer: C
At which level should the SLO be associated to have a device managed by FAST on a VMAX3?
At which level should the SLO be associated to have a device managed by FAST on a VMAX3?A . Storage GroupB . Device GroupC . Masking ViewD . Data PoolView AnswerAnswer: C
R2 devices
R2 devicesView AnswerAnswer: B
When transitioning from Adaptive Copy mode to SRDF/A mode, what is the minimum number of cycle switches required to reach data consistency?
When transitioning from Adaptive Copy mode to SRDF/A mode, what is the minimum number of cycle switches required to reach data consistency?A . 1B . 2C . 4D . 8View AnswerAnswer: B