When adding device pairs to an SRDF/Metro configuration using the -exempt option, what prevents a device pair from being added?
When adding device pairs to an SRDF/Metro configuration using the -exempt option, what prevents a device pair from being added?A . R2 device is larger than the R1 deviceB . Source group and device pair are in SRDF/S modeC . R1 device is the source of a TimeFinder data copyD...
What action is prevented by keeping the existing signature?
A storage administrator has mounted a snapshot of an existing datastore to the ESXi server and decided to keep its existing signature. What action is prevented by keeping the existing signature?A . Increasing the datastore sizeB . Replicating the datastoreC . Modifying the datastore configurationD . Restoring the datastoreView AnswerAnswer:...
What is a valid Host I/O bandwidth limit setting for this configuration?
A PowerMax parent Storage Group (SG) contains two child SGs: SG1 and SG2. What is a valid Host I/O bandwidth limit setting for this configuration?A . Parent SG: 500 SG1: NOLIMIT SG2: 1000B . Parent SG: 400 SG1: 500 SG2: NOLIMITC . Parent SG: 400 SG1: 500 SG2: 200D ....
What action is required on a PowerMax thin device before it can be deleted?
What action is required on a PowerMax thin device before it can be deleted?A . Unmap from front-end portsB . Remove from Storage GroupC . Set to Write DisableD . Set to Not ReadyView AnswerAnswer: A
The Output file of a linux host collection utility does not match the BCSD parser format. what could be the reason?
The Output file of a linux host collection utility does not match the BCSD parser format. what could be the reason?A . Incorrect LUNs specifiedB . Perform is not up to dateC . BSCD is incorrectly configuredD . OS patches are not up to dateView AnswerAnswer: D
Which Workload Type is recommended for a combination of small and large block I/O workloads?
A storage administrator uses Unisphere for PowerMax to provision new storage from a VMAX All Flash array. Which Workload Type is recommended for a combination of small and large block I/O workloads?A . DSSB . OptimizedC . OLTPD . NoneView AnswerAnswer: D
What is the best practice sizing guideline for front-end FA utilization on a two-engine PowerMax array?
What is the best practice sizing guideline for front-end FA utilization on a two-engine PowerMax array?A . 0.5B . 0.6C . 0.7D . 0.8View AnswerAnswer: C
What is the default HTTPS port assignment for communication of VSI/IAPI requests sent to REST API of Unisphere for PowerMax?
What is the default HTTPS port assignment for communication of VSI/IAPI requests sent to REST API of Unisphere for PowerMax?A . 5441B . 5443C . 8441D . 8443View AnswerAnswer: D
What is the cause of the error?
A PowerMax customer has an existing Masking View for a large database environment. The parent Storage Group in this Masking View has three child Storage Groups with different Service Levels (SLs). The customer has been experiencing some database performance issues and wants to set the SL to Platinum for all...
Match each management tool to its function.
Match each management tool to its function. View AnswerAnswer: