When connecting a PowerStore base enclosure to 2 expansion enclosures, match the base SAS ports in column A to their corresponding expansion LCC ports in column B
DRAG DROP When connecting a PowerStore base enclosure to 2 expansion enclosures, match the base SAS ports in column A to their corresponding expansion LCC ports in column B. View AnswerAnswer: Explanation: B B ---> B A A A ---> B B A B ---> A A B A --->...
How is the SSH session configured?
A Storage Administrator needs to connect through SSH to run svc commands. How is the SSH session configured?A . Appliance IP address using port 22B . NAS server IP address using port 26C . NAS server IP address using port 22D . Appliance IP address using port 26View AnswerAnswer: A
What is a step in configuring the ToR data switches for a Dell EMC PowerStore T?
What is a step in configuring the ToR data switches for a Dell EMC PowerStore T?A . Configure a port for the discovery laptopB . Create VLANs for NAS serversC . Create VLAN for vMotion networksD . Configure ports for management on native VLANView AnswerAnswer: A
What describes the power requirements for Dell EMC PowerStore?
What describes the power requirements for Dell EMC PowerStore?A . Lower model numbered systems require less AC line current than higher model numbered systemsB . T models require less total power than X modelsC . X models require less total power than T modelsD . Lower model numbered systems require...
How does the administrator proceed?
A Storage Administrator has an existing single appliance Dell EMC PowerStore 3000T cluster. An additional PowerStore 9000T has been purchased to add into the existing cluster. How does the administrator proceed?A . Additional VLTi links on the ToR switching must be configured for the 9000T to support the increased inter-switch...
What describes the SAS cabling when adding an expansion enclosure to a Dell EMC PowerStore, for each node and expansion enclosure side?
What describes the SAS cabling when adding an expansion enclosure to a Dell EMC PowerStore, for each node and expansion enclosure side?A . SAS cabling goes from existing A ports to new ports. At the last enclosure, SAS cabling returns from the A ports to the originating node’s B portsB...
Which Dell EMC PowerStore network uses an appliance backplane?
Which Dell EMC PowerStore network uses an appliance backplane?A . ICDB . MPIOC . Inter-nodeD . Inter-cluster managementView AnswerAnswer: C Explanation: Reference: https://blocksandfiles.com/2020/05/05/dell-emc-powerstore-midrange-array-launch-analysis/
How is a defective embedded module displayed in Dell EMC PowerStore Manager?
How is a defective embedded module displayed in Dell EMC PowerStore Manager?A . Orange with an empty stateB . Orange with a faulted stateC . Blue with a faulted stateD . Blue with an empty stateView AnswerAnswer: B
When a Dell EMC PowerStore node powers up in service mode, what are the commands and sequence used from the appliance SSH client to restore the node back to normal?
When a Dell EMC PowerStore node powers up in service mode, what are the commands and sequence used from the appliance SSH client to restore the node back to normal?A . svc_rescue_state clear svc_node rebootB . svc_node restart svc_rescue_state startC . svc_rescue_state normal svc_node startD . svc_node shutdown svc_rescue_state clearView...
Order the NDU operational steps
DRAG DROP Order the NDU operational steps. View AnswerAnswer: