What port must they use to start the installation?
An engineer wants to create a 4-node cluster after rack and stack. What port must they use to start the installation?A . COMB . FEC . BED . iDRACView AnswerAnswer: D Explanation: When an engineer wants to create a 4-node cluster after rack and stack, they must use the iDRAC...
What Is the correct sequence of steps to create the cluster?
DRAG DROP A platform engineer is creating a Dell PowerScale cluster using the Configuration Wizard. They have selected the Create a new cluster option. What Is the correct sequence of steps to create the cluster? View AnswerAnswer: Explanation: The correct sequence is: Accept End User License Agreement Configure cluster name...
Which resource should be consulted before performing any Dell PowerScale platform maintenance activities?
Which resource should be consulted before performing any Dell PowerScale platform maintenance activities?A . Dell SolVe OnlineB . Dell Technical SupportC . Dell iDRAC Service ModuleD . OneFS logs and error messagesView AnswerAnswer: A Explanation: Before performing any maintenance activities on a Dell PowerScale platform, it is crucial to consult...
What Is the correct sequence of steps to create the cluster?
DRAG DROP A platform engineer is creating a Dell PowerScale cluster using the Configuration Wizard. They have selected the Create a new cluster option. What Is the correct sequence of steps to create the cluster? View AnswerAnswer: Explanation: The correct sequence is: Accept End User License Agreement Configure cluster name...
Which three F200 components can a customer replace?
Which three F200 components can a customer replace? A. System Battery B. Network Interface Card C. CPU module D. DIMM E. NVDIMM BatteryView AnswerAnswer: A, B, D Explanation: When it comes to the Dell PowerScale F200 node, customers are allowed to replace certain components classified as Customer Replaceable Units (CRUs)....
What is a crucial step when replacing the failed node in the cluster?
An engineer replaced a failed node in a PowerScale H500 due to hardware issues. They must verity that the replacement node is functioning correctly. What is a crucial step when replacing the failed node in the cluster?A . Run a diagnostic test on the replacement node.B . Confirm that the...
What is the appropriate course of action to take before attempting to lift the chassis?
A platform engineer is installing a fully populated Dell PowerScale Gen 6 chassis in a customer rack. However, the equipment lift is broken. What is the appropriate course of action to take before attempting to lift the chassis?A . Remove the power supplies and hard drives, then rack the chassis.B...
What is a good practice when adding the nodes?
A platform engineer is adding three F600 nodes to a Dell PowerScale cluster. What is a good practice when adding the nodes?A . Wait 5 minutes between each additional node.B . Manually reboot each node before joining.C . Use the isi network output to show progress.D . Join new nodes...
What type of NIC is used for the external network on a Dell PowerScale F200 node?
What type of NIC is used for the external network on a Dell PowerScale F200 node?A . Dual port 10/25 GbE or dual port 40/100 GbEB . Single port 10 GbE or dual port 25/40 GbEC . Dual port 10/40 GbE or single port 100GbED . Dual port 10/100 GbEView...
What preparatory action is necessary to facilitate effective troubleshooting during and after PowerScale rack installation?
What preparatory action is necessary to facilitate effective troubleshooting during and after PowerScale rack installation?A . Creating a detailed network diagramB . Setting up a temporary command center near the rackC . Ensuring all tools and spare components are available on-siteD . Photographing each phase of the installation for referenceView...