What can the technician use to update the BIOS and iDRAC/ lifecycle Controller firmware?
A technician must update the firmware on a savor, but has no network connectivity. What can the technician use to update the BIOS and iDRAC/ lifecycle Controller firmware?A . OpenManage Server administrator DVDB . ftp dell.comC . NFS shareD . USB key with Dell Update PackageView AnswerAnswer: A
What does the LED indicate?
Refer to the exhibit. A system administrator wants to monitor information about the system using their smartphone and a Bluetooth connection. LED labeled 3 on the control panel is solid white. What does the LED indicate?A . The system is powered on.B . Quick SYNC 2 is ready to communicate.C...
Which memory operation modes are supported for a Dell PowerEdge R660?
Which memory operation modes are supported for a Dell PowerEdge R660?A . Optimizer and Persistent MemoryB . Optimizer and Dell Default ResilientC . Optimizer and MirrorD . Dell Default Resilient and MirrorView AnswerAnswer: B
What is the minimum number of components, beside the system board, required to POST?
What is the minimum number of components, beside the system board, required to POST?A . 1 PSU, 1 DIMM, and 1 CPU onlyB . 1 PSU, 1 CPU, 1 DIMM, and PERC SAS controllerC . 1 PSU and 1 CPU onlyD . PSUs, CPUs, and DIMMs as configured in BIOSView...
What is the minimum version of ESXi that should be used to avoid potential issues writing to the SD cards when running ESXi 7 from an IDSDM?
What is the minimum version of ESXi that should be used to avoid potential issues writing to the SD cards when running ESXi 7 from an IDSDM?A . 7.0 U2eB . 7.0 U2cC . 7.0 U3gD . 7.0 U3cView AnswerAnswer: B
What is the drive characteristic of a BOSS M.2 drive in a Dell EMC PowerEdge server?
What is the drive characteristic of a BOSS M.2 drive in a Dell EMC PowerEdge server?A . Single-level cellB . Write IntensiveC . Quad-level cellD . Read IntensiveView AnswerAnswer: A
Which characteristic of system management enables a company to reduce costs?
Which characteristic of system management enables a company to reduce costs?A . Integration with third-party toolsB . Multi-tenancy supportC . Rich management interfaceD . Automation of routine tasksView AnswerAnswer: D
Which application reduces the manual effort to update 500 Dell EMC PowerEdge R750 servers?
Which application reduces the manual effort to update 500 Dell EMC PowerEdge R750 servers?A . iDRAC9B . Lifecycle ControllerC . OpenManage EnterpriseD . OpenManage Server AdministratorView AnswerAnswer: C
Which redundancy options does this configuration supply?
A server is configured in a 1+1 power configuration with both PSUs connected to a single PDU. Which redundancy options does this configuration supply?A . PSU redundancy onlyB . PSU redundancy and PDU redundancyC . No redundancy unless each PSU is connected to a separate PDUD . PSU redundancy and...
What Is the cause of this Issue?
A technician wants to remotely log in to a server but finds that the IDRAC virtual Console feature Is not available. Use the simulator to explore the system. What Is the cause of this Issue? Note: It is necessary to dose (x) the simulator window before you can select a...