To which bus is the Dell EMC Unity 880F DPE connected?

To which bus is the Dell EMC Unity 880F DPE connected?A . 0B . 49C . 89D . 99View AnswerAnswer: D Explanation: The DPE on 480/F, 680/F, and 880/F systems is internally connected to Bus 99 which is a separate bus than the first SAS expansion port that is connected...

February 3, 2024 No Comments READ MORE +

How many PCI-E lanes are provided for Slot 0 and Slot 1 in Dell EMC Unity XT arrays?

How many PCI-E lanes are provided for Slot 0 and Slot 1 in Dell EMC Unity XT arrays?A . 8 for Slot 0; 8 for Slot 1B . 16 for Slot 0; 16 for Slot 1C . 8 for Slot 0; 16 for Slot 1D . 16 for Slot 0;...

February 3, 2024 No Comments READ MORE +

What are characteristics of D@RE on a Dell EMC Unity array?

What are characteristics of D@RE on a Dell EMC Unity array?A . Impacts array only during implementation Has minimal impact on performanceB . Does not impact array during implementation Has some impact on performance for a momentC . Impacts array for a moment after implementation Has no impact on performanceD...

February 3, 2024 No Comments READ MORE +

What is the minimum number of drives needed to expand the pool?

A customer wants to expand their Dell EMC Unity Hybrid system, which includes a pool of 64 drives in a RAID 5 (4+1) configuration. What is the minimum number of drives needed to expand the pool?A . 1B . 5C . 6D . 7View AnswerAnswer: C Explanation: DELL PDF document...

February 3, 2024 No Comments READ MORE +

Which term should you use in response?

A customer asks you about the maximum load of their new Dell EMC SC Series array. Which term should you use in response?A . MBB . IOPSC . CPU CyclesD . LatencyView AnswerAnswer: B Explanation: Reference: https://downloads.dell.com/manuals/common/sc-series-performance-availability-best-practices- dell-emc-4024-bp-sc_en-us.pdf

February 3, 2024 No Comments READ MORE +

The last two drive slots in a Dell EMC PowerStore 3000 are reserved for which type of drive?

The last two drive slots in a Dell EMC PowerStore 3000 are reserved for which type of drive?A . SAS SSDB . NVMe NVRAMC . NVMe SSDD . NVMe SCMView AnswerAnswer: B Explanation: Reference: https://volumes.blog/2020/05/05/whats-is-powerstore-part-2-hardware/#:~:text=On%20the%20PowerStore%201000%20and,(2)%20NVMe%20NVRAM%20devices.&text=PowerStore%20supports%20four%20types%20of,in%20specific%20locations%20and%20enclosures

February 3, 2024 No Comments READ MORE +

Which action does the storage administrator take to meet this requirement?

A database volume on a Dell PowerStore cluster has a Protection Policy that is applied with a single snapshot rule. The policy takes a snapshot every hour and retains them for 48 hours. The storage administrator must present a copy of the database volume to a test environment Which action...

February 3, 2024 No Comments READ MORE +

What does the embedded module provide?

A Dell Unity XT 480F system ships with two embedded modules, one for each SP. What does the embedded module provide?A . A Fiber Channel connectivityB . Field service onlyC . CNA connectivityD . ManagementView AnswerAnswer: D Explanation: The embedded module in a Dell Unity XT 480F system provides management...

February 3, 2024 No Comments READ MORE +

What should a technical architect advise the customer?

A customer wants to asynchronously replicate file data from a production Dell Unity 550F to a remote office in the same city with a UnityVSA When attempting to replicate one of the file systems the replication option is not available. What should a technical architect advise the customer?A . Asynchronous...

February 3, 2024 No Comments READ MORE +

Which Dell EMC Unity feature could reduce failover times?

A customer site has four NAS servers participating in MetroSync replication. Which Dell EMC Unity feature could reduce failover times?A . QoS Failover PolicyB . Cabinet FailoverC . SRDF MetroD . Consistency GroupsView AnswerAnswer: B

February 2, 2024 No Comments READ MORE +