Kitchen hood automatic fire-extinguishing systems shall be in accordance with the terms of their listing, the manufacturer's instructions, and which applicable NFPA standard?
Kitchen hood automatic fire-extinguishing systems shall be in accordance with the terms of their listing, the manufacturer's instructions, and which applicable NFPA standard?A . NFPA10B . NFPA17C . NFPA31D . NFPA33View AnswerAnswer: B Explanation: NFPA 17, Standard for Dry Chemical Extinguishing Systems, provides the requirements for the design, installation, maintenance,...
Which one of the following statements is true when requirements differ between NFPA1 and a referenced document?
Which one of the following statements is true when requirements differ between NFPA1 and a referenced document?A . NFPA1 requirements are enforcedB . The referenced document's requirements are enforcedC . The more restrictive requirements ate enforcedD . The board of appeals determines which requirements to enforceView AnswerAnswer: C Explanation: When...
Which of the following supporting documents is defined as illustrations and descriptions of a system component taken from a manufacturer's catalog?
Which of the following supporting documents is defined as illustrations and descriptions of a system component taken from a manufacturer's catalog?A . Cut sheetB . Data sheetC . Errata sheetD . Calculation sheetView AnswerAnswer: A Explanation: A "cut sheet" is a document that provides detailed illustrations, descriptions, specifications, and other...
What is the occupant load for a 3,240 ft2 (301 m2) single story, retail bicycle shop?
What is the occupant load for a 3,240 ft2 (301 m2) single story, retail bicycle shop?A . 32 peopleB . 108 peopleC . 124 peopleD . 126 peopleView AnswerAnswer: B Explanation: According to NFPA 101, Life Safety Code, the occupant load for a retail space is calculated by dividing the...
How many fire hydrants are located on the project site on plan L2?
How many fire hydrants are located on the project site on plan L2?A . ZeroB . OneC . TwoD . ThreeView AnswerAnswer: B Explanation: NFPA 1031, Standard for Professional Qualifications for Fire Inspector and Plan Examiner, does not provide specific details regarding the number of fire hydrants on a specific...
Exhibit
Exhibit. On plan sheet P01 fire protection symbols that are square with a solid dot indicateA . sprinkler head recessed pendent ordinary temperature quick responseB . sprinkler head upright intermediate temperature quick responseC . upright open sprinkler head for deluge systemD . sprinkler head recessed pendent intermediate temperature quick responseView...
What is the occupancy classification of a restaurant, if it has an occupant load greater than 50 people?
What is the occupancy classification of a restaurant, if it has an occupant load greater than 50 people?A . BusinessB . KitchenC . MercantileD . AssemblyView AnswerAnswer: D Explanation: According to NFPA 101, Life Safety Code, and NFPA 5000, Building Construction and Safety Code, a restaurant with an occupant load...
What is a plans review checklist used for?
What is a plans review checklist used for?A . An all-inclusive code requirement list used by both the plan submitter and plan reviewerB . A complete list of mandatory code requirements for specific plan reviewsC . A guideline for contractors to follow in organizing documents for the plan reviewerD ....
What is the maximum common path of travel permitted in a sprinklered educational occupancy?
What is the maximum common path of travel permitted in a sprinklered educational occupancy?A . 20 ft (6 m)B . 75 ft (23 m)C . 100 ft (30 m)D . 200 ft (61 m)View AnswerAnswer: C Explanation: According to NFPA 101, Life Safety Code, the maximum common path of travel...
The automatic fire sprinkler deluge system depicted m the stage area of plan F2 0 supplies how many fire sprinklers?
Exhibit. The automatic fire sprinkler deluge system depicted m the stage area of plan F2 0 supplies how many fire sprinklers?A . 6B . 8C . 16D . 24View AnswerAnswer: D Explanation: Based on the plan F2.0, the automatic fire sprinkler deluge system depicted in the stage area supplies a...