Which of the following differentiates the capabilities of IBM Cloud Manager with OpenStack from PowerVC?

Which of the following differentiates the capabilities of IBM Cloud Manager with OpenStack from PowerVC?A . Deploys images within the image repository with policy based placement.B . Generates custom expiration policies for each virtual machine.C . Captures existing virtual machines as images within the image repository.D . Provides virtual machine...

September 17, 2018 No Comments READ MORE +

Compared with the X86 solutions, which is no charge for the IBM analysis can be used to illustrate the value of IBM POWER server?

Customers compare POWER8ystems programs and X86 Solution ability to solve big data analysis. Compared with the X86 solutions, which is no charge for the IBM analysis can be used to illustrate the value of IBM POWER server?A . WLE (Workload Estimator)B . Perfomance NavigatorC . Eagle StudyD . SPT (System...

September 11, 2018 No Comments READ MORE +

A FlashSystem 840 attaches to a Power E870 via:

A FlashSystem 840 attaches to a Power E870 via:A . 16Gb Fibre Channel adapter.B . 8Gb GX++adapter.C . large write cache SAS adapter.D . Optical CXP converter adapter.View AnswerAnswer: B

September 7, 2018 No Comments READ MORE +

Which Power System RAS features are what POWER8 Enterprise-level models own uniquely?

Which Power System RAS features are what POWER8 Enterprise-level models own uniquely?A . processor instructions retryB . Dynamic processor replacementC . First Failure Data CaptureD . power management and thermal monitoring chip controllerView AnswerAnswer: B

September 5, 2018 No Comments READ MORE +

When migrating, which hardware can move from 770 to E870?

When migrating, which hardware can move from 770 to E870?A . EXP30 SSD I/OB . EXP24S SFF Gen2-bay drawerC . PCIe 5802/5877 I/O drawerD . Memory DIMMsView AnswerAnswer: B

September 2, 2018 No Comments READ MORE +

Which P0WER8 processor feature was announced to deliver balanced system performance?

Which P0WER8 processor feature was announced to deliver balanced system performance?A . Energy Scale TechnologyB . TPMD (Thermal Power Management Device)C . Level 4 (L4) cacheD . 20 partitions per coreView AnswerAnswer: C

August 30, 2018 No Comments READ MORE +

Which of the following documents is designed to mitigate risk as part of the acquisition of a new E880?

Which of the following documents is designed to mitigate risk as part of the acquisition of a new E880?A . TDA ChecklistB . SSIC ListingC . Power EstimatorD . Site EvaluationView AnswerAnswer: A

August 29, 2018 No Comments READ MORE +

What does IBM's Best Practice documentation recommend?

A customer recently purchased a Power E870 that includes redundant Service Processors, and would like to implement dual HMCs. What does IBM's Best Practice documentation recommend?A . Each HMC should be connected to both Service Processors on a separate private network.B . The HMCs should share the same DHCP range.C...

August 27, 2018 No Comments READ MORE +

Customers consider deploying a IBM data engine, applied to POWER SYSTEMS no solution.Which of the following will be used as a part of the solution?

Customers consider deploying a IBM data engine, applied to POWER SYSTEMS no solution.Which of the following will be used as a part of the solution?A . Native PCI Express to GPUB . CAPI Interface to FPGAC . CAPI Interface to GPUD . Native PCI Express to FPGAView AnswerAnswer: B

August 24, 2018 No Comments READ MORE +

In addition to assigning the adapter to the VIOS, what else needs to be done?

A customer has a tape drive directly connected to a 8Gb FC adapter to one LPAR which now needs to be shared between four LPARs. Network and storage are being accessed through NPiV and SEA. In addition to assigning the adapter to the VIOS, what else needs to be done?...

August 23, 2018 No Comments READ MORE +