Which feature will help prevent a system outage in the event of an uncorrectable error in memory being used by the hypervisor?

Which feature will help prevent a system outage in the event of an uncorrectable error in memory being used by the hypervisor?A . Active Memory ExpansionB . Active Memory MirroringC . Active Memory SharingD . Active Memory ProteXionView AnswerAnswer: B

March 23, 2018 No Comments READ MORE +

What P0WER8 enhancement provides greater RAS compared to prior generations of Power Systems?

What P0WER8 enhancement provides greater RAS compared to prior generations of Power Systems?A . First Failure Data CaptureB . Spare data lane on each fabric busC . Larger L3 memory cache modulesD . Redundant system clocksView AnswerAnswer: B

March 22, 2018 No Comments READ MORE +

What clients should consider?

A Customer wants the new E870 installed in existing 19-inch rack. What clients should consider?A . The system only comes with IBM rack for shipment. Customers need to remove it from the rack after the goods arrival.B . The system can only be installed to specific IBM rack. Do not...

March 18, 2018 No Comments READ MORE +

Achieve highly redundant VIO server on the S824, in addition to four Fibre Channel adapters, what options we also need?

Achieve highly redundant VIO server on the S824, in addition to four Fibre Channel adapters, what options we also need?A . 4 Ethernet cards, two processor cardsB . 2 Ethernet cards, one PCLe riserC . 4 Ethernet cards, one processor cardD . 4 Ethernet cards, two PCLe risersView AnswerAnswer: A

March 15, 2018 No Comments READ MORE +

When utilizing dual VIO Servers, which of the following simplifies storage management for the system administrator in a Fiber Channel SAN environment?

When utilizing dual VIO Servers, which of the following simplifies storage management for the system administrator in a Fiber Channel SAN environment?A . SASB . NPIVC . SSDD . VSCSIView AnswerAnswer: B

March 15, 2018 No Comments READ MORE +

Which Linux operating system needs to be loaded to install PowerVC?

Customers want to implement a private cloud on a Linux Power server. Which Linux operating system needs to be loaded to install PowerVC?A . UbuntuB . SUSEC . RHELD . DebianView AnswerAnswer: C

March 14, 2018 No Comments READ MORE +

Which feature of IBM Cloud Orchestrator (ICO) will distinguish it with IBM Cloud Manager with OpenStack (ICM)?

Which feature of IBM Cloud Orchestrator (ICO) will distinguish it with IBM Cloud Manager with OpenStack (ICM)?A . system images directory can be used for deploymentB . for built on ultiple Hypervisor cloud managementC . management including z System cloudD . Customizable, strong workflowView AnswerAnswer: D

March 9, 2018 No Comments READ MORE +

What kind of characteristics can provide this power?

A customer plan to integrate the workload, but hope in the future when their logical partitions changes occurred in the workload, the flexibility to shift from virtual I/O to physical I/O. What kind of characteristics can provide this power?A . LIVE Partition MobilityB . Shared Ethernet adapterC . NPIVD ....

March 5, 2018 No Comments READ MORE +

Which characteristics of the POWER8 system can optimize Big Data solutions?

Which characteristics of the POWER8 system can optimize Big Data solutions?A . 40GbE FCoE adapterB . IO extension drawerC . Memory bandwidthD . internal separation betrayalView AnswerAnswer: C

March 1, 2018 No Comments READ MORE +

Compared with X86, which of the following is a POWER processor in the benefits of big data analytics implementation?

Compared with X86, which of the following is a POWER processor in the benefits of big data analytics implementation?A . BLU accelerator unitB . more number of threads per coreC . dual-chip moduleD . 22 nanometer technologyView AnswerAnswer: B

February 28, 2018 No Comments READ MORE +