What prevents the system shipped?
Customer has ordered a E870.System has been constructed well, but cannot be shipped. What prevents the system shipped? A. IBM systems support representatives not complete the pre-installation site to access. B. has not completed mandatory pre-installation TDA. C. pre-TDA found that there are some problems can be corrected, but which...
Compared to x86, what feature of POWER8 processor technology permits more efficient processor core utilization to support highly threaded applications?
Compared to x86, what feature of POWER8 processor technology permits more efficient processor core utilization to support highly threaded applications?A . CAPIB . Decimal floating point unitC . L4 cachesD . SMT8View AnswerAnswer: D
What should be proposed to the customer?
A P0WER6 customer is considering an upgrade to a new Power System, and needs to ensure availability at a DR site. The recovery point must be as close to current as possible without going to continuous availability. Recovery time must be less than four hours. What should be proposed to...
What should be the proper processes, to enable customers to more days?
Customers have a E870, the current processor and memory usage for elastic Capacity on Demand (CoD).They have run out of all available processors enable several days. What should be the proper processes, to enable customers to more days?A . Customers must permanently activated processorB . Processing MES orders, their usage...
Which offering supports RHEL workloads on the E870?
A customer has an E870 installed, and is considering migrating a RHEL 6 workload from an x86 system. Which offering supports RHEL workloads on the E870?A . PowerVM Lx86B . Workload Partitions for Linux (WPL)C . Integrated Facility for Linux (IFL)D . PowerKVMView AnswerAnswer: C
VIOS shared storage pool SAN management expertise for lack of customers, can provide benefits?
VIOS shared storage pool SAN management expertise for lack of customers, can provide benefits?A . provide to the VIOS client direct partition storage ability.B . the data file to the end user is responsible for.C . let SAN administrator more flexible data on the back-end storage.D . provide the capability...
Which of the following is true for an IBM Power Enterprise processor pool?
Which of the following is true for an IBM Power Enterprise processor pool?A . The master HMC is defined using an client-created XML file which lists serial number of each Enterprise Pool Participate (EPP).B . A server is deleted from, or added to, the pool when the client creates a...
Compared with POWER7 systems architecture, which component of POWER8 system architecture can provide better RAS capability?
Compared with POWER7 systems architecture, which component of POWER8 system architecture can provide better RAS capability?A . On-chip AcceleratorB . PCIe Gen3C . CAPID . CDIMMSView AnswerAnswer: D
What is the earliest Power server generation that is supported with this HMC level?
A customer has older generations of Power servers that they want to manage with their E870 server from the same 7042-CR8 HMC running V8R8.2.0. What is the earliest Power server generation that is supported with this HMC level?A . POWER6B . POWER7C . POWER4D . POWER5View AnswerAnswer: A
Which of the following can effectively solve customers' worry of single point of failure?
Customers are more worried about a single point of failure (SPOF), because there is a system control unit (SCU) in the proposed E870 solution. Which of the following can effectively solve customers' worry of single point of failure?A . redundant SAN fiber optic connector is used for connecting SCU to...