Which action resolves the issues?
An attempt to use a global vNIC redundancy template pair results in a service profile that fails to apply. Which action resolves the issues?A . Create the peer names before creating the templates. B. Assign the secondary template first, and then set the peer name. C. Assign both templates simultaneously....
What is the cause of the issue?
Refer to the exhibit. The connection between a Cisco Nexus 5548UP switch and a Cisco MDS switch fails to initialize. What is the cause of the issue?A . VSAN 1 is suspended. B. The SFP is unsupported. C. Trunk mode must be activated. D. The interface is in an incorrect...
What is the cause of this error?
One of Cisco Nexus Series interfaces has become errdisabled with the error message “DCX-No ACK in 100 PDUs”. What is the cause of this error?A . The host has not responded to the Control Sub-TLV DCBX exchanges of the switch. B. The acknowledgement number in the server response has not...
Which action resolves the issue?
Refer to the exhibit. customer reports that all Intra-EPG isolation stopped working within a bare-metal tenant. Postman is running on a machine to get information from the APIC in case of orchestration failure. Which action resolves the issue?A . Match encap="vlan-10" and primaryEncap="vlan-110" B. Modify the GET command to reference...
What is a possible cause of the issue?
Refer to the exhibit. When an engineer inserts 8-Gb FC SFP port 15 on a Cisco UCS Fabric Interconnect, the port fails. What is a possible cause of the issue?A . Port 15 is configured as an Ethernet port. B. Port 15 is configured for 4-Gb FC. C. Port 15...
Which action resolves the issue?
Refer to the exhibit. The scheduler job fails to run. Which action resolves the issue?A . Change the file name. B. Configure the authentication credentials. C. Change the TFTP server address. D. Configure the RBAC authentication.View AnswerAnswer: A
Which action resolves the issue?
Refer to the exhibit. The scheduler was configured to save the running-config automatically daily. However, the scheduler is returning the error presented. Which action resolves the issue?A . Reconfigure the scheduler using the admin user B. Use the kstack attribute for copying the configuration file C. Remove vrf management from...
Enable the firmware on an adapter.
Enable the firmware on an adapter.View AnswerAnswer: B
Which action resolves the issue?
Refer to the exhibit. Cisco UCS Manager is being upgraded using the Auto Install feature, but the FSM fails. Which action resolves the issue?A . Acknowledge the primary fabric interconnect. B. Remove the service pack from the subordinate fabric interconnect. C. Clear the startup version of the default infrastructure pack....
A firmware upgrade on a fabric interconnect fails. A bootflash contains a valid image
DRAG DROP A firmware upgrade on a fabric interconnect fails. A bootflash contains a valid image. Drag and drop the recovery steps from the left onto the correct order on the right. View AnswerAnswer: