Which interface should be used to meet these requirements?

An engineer must configure an interface for managing and orchestrating a Cisco Nexus device. The interface must be operational if the data and control planes crash, support IPv4 and IPv6 addressing, and have been access to its own VRF instance . Which interface should be used to meet these requirements?A...

June 4, 2021 No Comments READ MORE +

Which two automation tools must be used to meet these requirements?

A company must introduce a scalable network automation tool to deploy, configure, and manage thousands of network device and service. The company servers already have been security-hardened and must not have any additional software installed on team. The security policy mandates the use of a secure communication protocol that support...

June 4, 2021 No Comments READ MORE +

Which automation tool should be used to meet these requirements?

An engineer manages hundreds of Cisco Nexus Series and 9000 Series Switches that are installed at several data centers and wants to use one of the built-in automation tools of the Cisco NX-OS Guest Shell to automate daily activities. The engineer requires a tool that uses imperative language, has extensive...

June 4, 2021 No Comments READ MORE +

Which two components should be included in the design?

A network design must include a solution to run CLI commands remotely on Cisco Nexus 9000 Series Switches. The customer's security policy requires secure login credentials and an encrypted underlying transport. The command output will be processed using tools that support XML or JSON encoding . Which two components should...

June 4, 2021 1 Comment READ MORE +

Which two configurations allow for routing traffic between two VDCs? (Choose two.)

Which two configurations allow for routing traffic between two VDCs? (Choose two.)A . Connect the VDCs to an external Layer 3 device.B . Cross-connect the ports between the VDCs.C . Create VRF-aware software infrastructure interfaces.D . Create a policy map in the default VDC that routes traffic between the VDCs.E...

June 4, 2021 No Comments READ MORE +

Which technology meets these requirements?

An engineer must build a VXLAN flood-and-learned network. The customer requires the solution to be based on the IETF documented practice in RFC 7348. The solution must use broadcast, unknown unicast, and multicast (BUM) and include the efficient BUM and short BUM replication modes that use only shared trees ....

June 3, 2021 No Comments READ MORE +

What is an advantage of using OTV as compared to VPLS for data center redundancy?

What is an advantage of using OTV as compared to VPLS for data center redundancy?A . prevents loops on point-to-point linksB . provides head-end replicationC . uses a proactive MAC advertisementD . provides full-mesh connectivityView AnswerAnswer: A Explanation: Reference: https://community.cisco.com/t5/data-center-documents/understanding-overlay-transport-virtualization-otv/ta-p/3151502#toc-hId-1043251551

June 3, 2021 No Comments READ MORE +

A failure occurs on the network between two BFD and OSPF neighbors

DRAG DROP A failure occurs on the network between two BFD and OSPF neighbors. Drag and drop the protocol actions from the left into the correct order on the right. View AnswerAnswer:

June 3, 2021 No Comments READ MORE +

Which two technologies meet this requirement?

An engineer is designing a Multichassis EtherChannel topology in which two switches must appear as a single device to a third downstream switch? Which two technologies meet this requirement? (Choose two.)A . HSRPB . VSSC . vPCD . 802.1qE . FEXView AnswerAnswer: B,C Explanation: Reference: https://www.cisco.com/c/dam/en/us/products/collateral/switches/nexus-7000-series-switches/C07-572835-00_NX-OS_vPC_DG.pdf

June 3, 2021 No Comments READ MORE +

Which two methods mitigate congestion in a SAN network? (Choose two.)

Which two methods mitigate congestion in a SAN network? (Choose two.)A . Configure ER_RDY to allow splitting of each ISL between switches into separate virtual links.B . Use the port-monitor command to detect slow drain devices.C . Configure the port channel to enable individual buffer-to-buffer credits.D . Configure the port...

June 3, 2021 No Comments READ MORE +