Place a firewall between the VDCs.
Place a firewall between the VDCs. D. 1) Create a separate VRF for the testing and development environments. 2) Control reachability by using firewall access policies.View AnswerAnswer: D
Which two types of service profile templates does Cisco UCS support? (Choose two.)
Which two types of service profile templates does Cisco UCS support? (Choose two.)A . initial B. permanent C. updating D. temporary E. connectedView AnswerAnswer: A,C Explanation: Reference: https://www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/config/guide/141/UCSM_GUI_Configuration_Guide_141_chapter28.html#concept_C9D27CE2AA1245EA976DAA79F5BC6808
Which Cisco HyperFlex deployment model meets these requirements?
An engineer must deploy a Cisco HyperFlex system at two data centers. For redundancy reasons, the setup must achieve data protection in case of an entire site failure. The data must be available on both sites at all times to keep the recovery time objective to a minimum. Which Cisco...
Which address pool is used when a vHBA template is created?
Which address pool is used when a vHBA template is created?A . MAC B. WWPN C. IP D. UUIDView AnswerAnswer: B Explanation: Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/2-1/b_UCSM_GUI_Configuration_Guide_2_1/b_UCSM_GUI_Configuration_Guide_2_1_chapt er_011010.html
Which two components must be selected to meet these requirements?
An engineer must implement an iSCSI storage connectivity in the existing Cisco UCS environment. The environment is based on Cisco UCS -Series rack server, Cisco Nexus 1000V Series Switches, and VMware ESXi hosts. The implementation must meet these requirements: ✑ Provide multipathing and high availability in the event of a...
Which design resolves this issue?
An end user is experiencing network latency when accessing a database in a disaster recovery site. The monitoring team concluded that the database was writing simultaneously to the storage arrays on the primary and disaster recovery sites. Which design resolves this issue?A . asynchronous replication between data centers B. synchronous...
Which mode must be enabled on a Cisco UCS Fabric Interconnect to connect directly to a storage array?
Which mode must be enabled on a Cisco UCS Fabric Interconnect to connect directly to a storage array?A . NPIV mode B. FC end-host mode C. NPV mode D. FC switching modeView AnswerAnswer: D Explanation: Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/Storage-Mgmt/3-1/b_UCSM_GUI_Storage_Management_Guide_3_1/b_UCSM_GUI_Storage_Management_Guide_3_1_chapter_01110.html
Which two methods mitigate congestion in a SAN network? (Choose two.)
Which two methods mitigate congestion in a SAN network? (Choose two.)A . Configure ER_RDY to allow splitting of each ISL between switches into separate virtual links. B. Use the port-monitor command to detect slow drain devices. C. Configure the port channel to enable individual buffer-to-buffer credits. D. Configure the port...
Which technology accomplishes these goals?
An engineer seeks a solution to retrieve routing information from Cisco Nexus switches. The data must be exported to a web application in a JSON or XML data format for monitoring and must be encrypted during transmission. The solution must not require extensive knowledge to support and should be simple...
When planning to deploy a load-balancing service as a managed node, which ACI configuration must be included?
When planning to deploy a load-balancing service as a managed node, which ACI configuration must be included?A . BGP ECMP B. Layer 4 to Layer 7 device package C. inline load-balancing device D. ITDView AnswerAnswer: B Explanation: Reference: https://www.cisco.com/c/en/us/td/docs/switches/datacenter/aci/apic/sw/1-x/ACI_Best_Practices/b_ACI_Best_Practices/b_ACI_Best_Practices_chapter_0110.html