Which three statements about powering down a Cisco UCS C-Series Rack-Mount Server to perform maintenance or replacement are true? (Choose three.)
Which three statements about powering down a Cisco UCS C-Series Rack-Mount Server to perform maintenance or replacement are true? (Choose three.)A . Standby power mode: Power is supplied only to the service processor and the cooling fans, and it is safe to power off the server from this mode.B ....
Which Cisco NX-OS command displays kernel uptime?
Which Cisco NX-OS command displays kernel uptime?A . show moduleB . show versionC . show licenseD . show bootE . show interfaceView AnswerAnswer: B
What is the correct path to verify the Overall Status of Chassis 1 | Server 3?
What is the correct path to verify the Overall Status of Chassis 1 | Server 3?A . Equipment Tab > Chassis > Chassis 1 > Servers > Server 3 Status tabB . Equipment Tab > Chassis > Chassis 1 > Servers > Server 3 General tabC . Equipment Tab >...
Which command can be used to exit to EXEC mode from this current mode? switch(config-if) #
Which command can be used to exit to EXEC mode from this current mode? switch(config-if) #A . Ctrl-CB . Ctrl-LC . quitD . exitE . endView AnswerAnswer: E
Which Cisco MDS chassis supports the 48-Port 16-Gbps Fibre Channel Switching Module?
Refer to the exhibit. Which Cisco MDS chassis supports the 48-Port 16-Gbps Fibre Channel Switching Module?A . MDS 9509B . MDS 9513C . MDS 9710D . MDS 9506View AnswerAnswer: C
Which item does A represent?
Refer to the exhibit. Which item does A represent?A . Emulex Adapter Card for Cisco UCS B420 M3 Blade ServersB . Virtual Interface Card for Cisco UCS B420 M3 Blade ServersC . mLOM for Cisco UCS B420 M3 Blade ServersD . Virtual Emulex Adapter Card for Cisco UCS B420 M3...
Where is the best place to find the B200 BIOS version used in a specific Cisco UCS Manager version?
Refer to the exhibit. Where is the best place to find the B200 BIOS version used in a specific Cisco UCS Manager version?A . A - Installed FirmwareB . B - PackagesC . C - ImagesD . D - Capability CatalogE . E - Management ExtensionView AnswerAnswer: B
What is the name of this rack-mount server?
Refer to the exhibit. What is the name of this rack-mount server?A . Cisco UCS C220 Rack-Mount ServerB . Cisco UCS C240 Rack-Mount ServerC . Cisco UCS C420 Rack-Mount ServerD . Cisco UCS C460 Rack-Mount ServerView AnswerAnswer: C
Which item does F represent?
Refer to the exhibit. Which item does F represent?A . HDD 1B . TFP ModuleC . SuperCap ModuleD . CPU 2E . CMOS BatteryView AnswerAnswer: D
To do a password recovery on a Cisco NX-OS Switch, which option shows the correct syntax to display the bootflash contents at the switch(boot)#?
To do a password recovery on a Cisco NX-OS Switch, which option shows the correct syntax to display the bootflash contents at the switch(boot)#?A . display bootflash:B . show bootflash:C . dir bootflash:D . find bootflash:View AnswerAnswer: C