The valid value for a decimal floating point number of type decfloat34 is a number between 1E6145 and -1E-6143for a negative number, 0, and +1E-6143 to 1E6145.
The valid value for a decimal floating point number of type decfloat34 is a number between 1E6145 and -1E-6143for a negative number, 0, and +1E-6143 to 1E6145.A . TrueB . FalseView AnswerAnswer: A
In addition to the primary key of an internal table, how many secondary indexes can you define for an internal table? Please choose the correct answer.
In addition to the primary key of an internal table, how many secondary indexes can you define for an internal table? Please choose the correct answer.A . 0B . 1C . 15D . 10View AnswerAnswer: C
What happens if the application senda a type E message during the check_CB module processing?
CORRECT TEXT A screen has the following PAI flow logic: PROCESS AFTER INPUT FIELD A MODULE check_A FIELD A MODULE check_B CHAIN. FIELD:C,D MODULE check_CD ENDCHAIN FIELD:C,B. MODULE check_CB ENDCHAIN What happens if the application senda a type E message during the check_CB module processing? Please choose the correct answer....
Which class is used to define a reference for an instance of the ALV Object Model?
Which class is used to define a reference for an instance of the ALV Object Model?A . Class CL_GUI_ALV_GRIDB . Class CL_GUI_CUSTOM_CONTAINERC . Class CL_SALV_TABLEView AnswerAnswer: C
Which tools are available to assist you to diagnose performance issues in your program?
Database access can occupy most of the runtime in an ABAP program. Which tools are available to assist you to diagnose performance issues in your program? Select all that apply}A . ABAP Objects Runtime Analysis (Transaction ATRA)B . Performance Trace (Transaction ST05)C . ABAP Trace (Transaction SAT)D . ABAP Objects...
The constructor method is called automatically when you create an instance of the class.
The constructor method is called automatically when you create an instance of the class.A . TrueB . FalseView AnswerAnswer: A
Internal tables cannot have a deep or nested structure in their line type
Internal tables cannot have a deep or nested structure in their line typeA . FalseB . TrueView AnswerAnswer: A
A replacement object can be defined for a pooled table.
A replacement object can be defined for a pooled table.A . TrueB . FalseView AnswerAnswer: B
Which class is used to define a reference for an instance of the ALV Object Model?
Which class is used to define a reference for an instance of the ALV Object Model?A . Class CL_GUI_ALV_GRIDB . Class CL_GUI_CUSTOM_CONTAINERC . Class CL_SALV_TABLEView AnswerAnswer: C
You can modify an internal table by using the UPDATE statement
You can modify an internal table by using the UPDATE statementA . FalseB . TrueView AnswerAnswer: A