NFPA CFPS Certified Fire Protection Specialist (CFPS) Online Training
NFPA CFPS Online Training
The questions for CFPS were last updated at Feb 23,2025.
- Exam Code: CFPS
- Exam Name: Certified Fire Protection Specialist (CFPS)
- Certification Provider: NFPA
- Latest update: Feb 23,2025
Typical fire pump drivers reach maximum brake horsepower between
- A . 65-85% of rated capacity.
- B . 90-100% of rated capacity.
- C . 110-125% of rated capacity.
- D . 140-170% of rated capacity.
Potassium bicarbonate is a dry chemical agent considered to be twice as effective as
- A . Asodium bicarbonate.
- B . monoammonium phosphate.
- C . sodium chloride.
- D . potassium sulfide.
The primary design approach to mitigate the effect of wind on smoke movement in high-rise buildings is based on
- A . outside temperature.
- B . height of the building.
- C . tightness of the building.
- D . fire department access.
Response Time Index (RTI) is a value applicable to
- A . Amount of time required for water to reach the most remote sprinkler.
- B . Measure of thermal sensitivity of the air evacuation device of a dry pipe sprinkler system.
- C . Measure of thermal sensitivity of a sprinkler’s activation.
- D . Measure of thermal sensitivity of a wet pipe sprinkler system’s alarm device.
All of the following must be demonstrated to prove professional negligence under standard of care EXCEPT
- A . breach of contract.
- B . owing of a duty.
- C . causation.
- D . damages or harm.
The ignition test method that exposes the specimen to a known heat flux from a tungsten-quartz heater is referred to as a
- A . fire propagation apparatus.
- B . lateral ignition apparatus.
- C . cone calorimeter.
- D . intermediate-scale calorimeter.
What type of fire pump has a pressure range that can exceed 300 psi (2,068 kPa)?
- A . Horizontal-end suction
- B . Suction in-line
- C . Split case
- D . Vertical turbine
Which OSHA regulation addresses storage and handling of liquefied petroleum gas?
- A . 1910.107
- B . 1910.108
- C . 1910.110
- D . 1910.119
When using the Fire Safety Concept Tree to assess life safety for occupancies, the major categories of strategies include managing the fire, managing exposed occupants, and
- A . emergency response.
- B . occupant notification.
- C . fire prevention.
- D . risk classification.
Environmental Protection Agency standards require solid waste be treated as hazardous if it is a listed waste and/or meets the characteristics prescribed by the standard for toxicity, reactivity, corrosivity, and
- A . solubility.
- B . compactability.
- C . lignitability.
- D . treatability.