Exhibit.
For the included figure, which dimension is the tread depth?
- A . A
- B . B
- C . C
- D . A+B
Exhibit.
What is the occupant load of the stage on plan A5?
- A . 56 people
- B . 58 people
- C . 60 people
- D . 62 people
A fire department access road shall be provided such that any portion of an unsprinklered facility is located no more than what maximum distance from the access road’-‘ A.
- A . 50 ft (15 m)
- B . 150 ft (46 m)
- C . 300 ft (91 m)
- D . 450 ft (137 m)
Which of the following supporting documents is defined as illustrations and descriptions of a system component taken from a manufacturer’s catalog?
- A . Cut sheet
- B . Data sheet
- C . Errata sheet
- D . Calculation sheet
Where field conditions necessitate a substantial change in the approved plans,
- A . revised drawings may be required by the AHJ.
- B . no action is necessary on the part of the applicant.
- C . revised drawings must be submitted to the applicant.
- D . no action is necessary on the part of the AHJ.
The symbol above is a representation of which one of the following?
- A . Riser
- B . Reducer
- C . Check valve
- D . Post-indicator valve
What is a plans review checklist used for?
- A . An all-inclusive code requirement list used by both the plan submitter and plan reviewer
- B . A complete list of mandatory code requirements for specific plan reviews
- C . A guideline for contractors to follow in organizing documents for the plan reviewer
- D . An internal guide for plans examiners to avoid overlooking important design aspects
When does a new model code take effect within a jurisdiction?
- A . When it is adopted into law by a jurisdiction
- B . When it is voted into law by the people of a jurisdiction
- C . When it is published by the code-making body
- D . When it is approved by the voting members of the code-making body
If a sprinkler system is supplied with water from a gravity tank, the gravity tank shall be installed in accordance with what standard in order to be acceptable as a source of water?
- A . NFPA13
- B . NFPA20
- C . NFPA22
- D . NFPA24
Exhibit.
All work performed on the sprinkler system described on plan sheet F0.1 shall be in accordance with which NFPA documents?
- A . NFPA13andNFPA24
- B . NFPA13andNFPA25
- C . NFPA14andNFPA24
- D . NFPA15andNFPA25