What is the cause of this error?

While expanding a 200 GB LUN in an ONTAP 9.4 system, the following error is observed: What is the cause of this error?A . The volume auto-grow is disabled. B. The LUN reached maximum capacity. C. The LUN can be expanded up to 10 times its original size. D. Space...

May 13, 2023 No Comments READ MORE +

Which two port personality combinations are valid for the onboard UTA2 ports on a FAS8040 controller?

Which two port personality combinations are valid for the onboard UTA2 ports on a FAS8040 controller?A . e0e/0e C fc e0f/0f C fc e0g/0g C cna e0h/0h Ccna B. e0e/0e C fc e0f/0f C cna e0g/0g C fc e0h/0h Ccna C. e0e/0e C fc e0f/0f C fc e0g/0g C fc...

May 13, 2023 No Comments READ MORE +

What is the recommended minimum of data LIFs per node for iSCSI in a dual-fabric configuration with four SVMs?

What is the recommended minimum of data LIFs per node for iSCSI in a dual-fabric configuration with four SVMs?A . 8 B. 12 C. 16 D. 4View AnswerAnswer: A

May 12, 2023 No Comments READ MORE +

Physical Reallocation of a SnapMirror source volume increases the amount of data to transfer for the next SnapMirror update.

Physical Reallocation of a SnapMirror source volume increases the amount of data to transfer for the next SnapMirror update.A . True B. FalseView AnswerAnswer: B

May 12, 2023 No Comments READ MORE +

An aggregate is composed of twelve 36-Gigabyte disks. A drive fails and only 72-Gigabyte spare disks are available. Data ONTAP will then perform what action.

An aggregate is composed of twelve 36-Gigabyte disks. A drive fails and only 72-Gigabyte spare disks are available. Data ONTAP will then perform what action.A . Chooses a 72-Gigabyte disk and use it as is. B. Chooses a 72-Gigabyte disk and right-size it. C. Halts after 24 hour of running...

May 12, 2023 No Comments READ MORE +

What is the problem?

Create datastore and its containing LUNS and volumes. In step 8, you are not able to see the LUNs you provisioned on your storage controller. When you run igroup show you see the ESX host’s initiators; however, they are listed “not logged in”. What is the problem? A. You need...

May 12, 2023 No Comments READ MORE +

Which two components must be verified for a supported NetApp SAN confutation? (Choose two.)

Which two components must be verified for a supported NetApp SAN confutation? (Choose two.)A . host memory B. host GPU C. host multipath D. host bus adapterView AnswerAnswer: CD

May 12, 2023 No Comments READ MORE +

Referring to the exhibit, what is needed to allow hosts to log into the iSCSI target?

Exhibit: You are asked to serve iSCSI LUNs in an existing SVM on your AFF A220 using ONTAP 9.5. You verified that the iSCSI license is configured on your cluster and that the iSCSI protocol is enabled. Referring to the exhibit, what is needed to allow hosts to log into...

May 12, 2023 No Comments READ MORE +

In this scenario, what would be the reason for the disconnects?

A company has 20 ESX hosts. Ten of the hosts are connected using FC, and the rest are connected over iSCSI. The FC host HBA queue depth is set to 32, and the iSCSI LUN queue depth is set to 64. The FC hosts are now experiencing random connectivity issues....

May 12, 2023 No Comments READ MORE +

Referring to the exhibit, what happens when you change the type for port 1a from target to initiator?

Referring to the exhibit, what happens when you change the type for port 1a from target to initiator? A . The port type for 1a changes to initiator, and you must reboot the controller for the changes to take effect. B. You receive an error message that you must take...

May 12, 2023 No Comments READ MORE +