On which two types of ports would data LIFs be hosted? (Choose two.)
On which two types of ports would data LIFs be hosted? (Choose two.)A . console RJ45 portB . management e0M portC . physical ports that are not part of interface groupsD . physical ports or interface groups that host VLANsView AnswerAnswer: CD Explanation: Physical ports that are not part of...
Which three disk shelf types are supported in clustered Data ONTAP 8.3? (Choose three.)
Which three disk shelf types are supported in clustered Data ONTAP 8.3? (Choose three.)A . DS14-MK4-FCB . DS4486C . DS14-MK2-FCD . DS14E . DS14-MK2-ATView AnswerAnswer: ABE
After you complete an aggregate relocate, what happens to the relocated aggregate?
After you complete an aggregate relocate, what happens to the relocated aggregate?A . The SFO aggregate moves from the current node to the partner node in the same HA pair.B . The CFO aggregate moves from the current node to the partner node in the same HA pair.C . The...
Which statement about the cluster interconnect switch configuration is true?
Which statement about the cluster interconnect switch configuration is true?A . ISL ports are defined based on the NetApp RCF file.B . ISL ports are defined based on the NetApp sysconfig file.C . ISL ports are optional.D . ISL ports use factory default settings.View AnswerAnswer: A
What will the storage aggregate create Caggregate aggr0_rg0 Cdiskcount 40 Cmaxraidsize 20 Cnodes cl-01 Cdisktype SAS command do?
What will the storage aggregate create Caggregate aggr0_rg0 Cdiskcount 40 Cmaxraidsize 20 Cnodes cl-01 Cdisktype SAS command do?A . It creates a new aggregate named aggr0_rg0 with one RAID-DP RAID group of 40 SAS drives on cl-01.B . It creates a new aggregate named aggr0_rg0 with two RAID4 RAID groups...
When a pNFS client is connected on a LIF on node 1 of a 4-node clustered Data ONTAP pNFS 4.1 vServer, and node 2 performs a storage takeover (SFO) of node 1, and LIFs failover to node 3, which statement is true?
When a pNFS client is connected on a LIF on node 1 of a 4-node clustered Data ONTAP pNFS 4.1 vServer, and node 2 performs a storage takeover (SFO) of node 1, and LIFs failover to node 3, which statement is true?A . The pNFS redirects access to a LIF...
What setting caused this behavior?
You execute a node takeover on a 2-node HA cluster for scheduled maintenance. Ten minutes later, you investigate the system and find that both nodes are online and active. Looking at the logs, you see that the node did complete the failover but that it completed a giveback after the...
What is the correct order of network tasks that are required before you create the LIF?
You have a new cluster and must create a LIF on a port that uses LACP and a VLAN. What is the correct order of network tasks that are required before you create the LIF?A . VLAN -> ifgroup -> add port to broadcast domainB . add port to broadcast...
What kind of structure can be deduplicated?
What kind of structure can be deduplicated?A . A FlexVolB . An aggregateC . a qtreeD . A diskView AnswerAnswer: AB
Which two solutions are valid for clustered Data ONTAP MetroCluster?
Which two solutions are valid for clustered Data ONTAP MetroCluster? (Choose two.)A . four nodes at each siteB . two nodes at each siteC . FAS2500 series controllerD . FAS3200 series controllersView AnswerAnswer: B D